Rework Starter/Generator (Fig. 24)
NOTE:  Rework to the  starter/generator must be  per-
formedbyaproperlytrainedtechnicianusingthecorrect
tools and equipment for testing and reworking electrical
motors and generators.  It may be more  economically
feasible to replace the starter/generator than have it re-
worked.
Detail
Minimum commutator diameter
Commutator concentricity to the shaft
Commutator machining limit per cut
Insulator depth between commutator bars
Armature insulation resistance
Dielectric (insulation strength)
Starter field coil resistance
Specification
1.575 inches (40 mm)
0.0003 inch (0.008 mm)
0.005 inch (0.127 mm)
0.020 inch (0.5 mm)
0.2 Mohm at 500 VDC
500 VDC for one minute with no insulation break down
2.38 to 2.44 ohms at 20
C (68 F)
o             o
Generator field coil resistance
o             o
0.041 ohm for F1 and 0.043 ohm for F2 at 20 C (68 F)
Electrical System
Page 6 -- 24
Workman MD/MDX
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 178 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website