7.
Connect a digital multimeter (set to amps) between
the negative battery post and the negative (ground)
cable connector. The reading should be less than 0.1
amp. If the reading is 0.1 amp or more, the unit’s electri-
cal system should be tested and repaired.
Battery
Reserve
Capacity
(Minutes)
Battery Charge Level
(Percent of Fully Charged)
75%
50%
25%
0%
8.
Connect negative (ground) cable connector to the
negative battery post. Tighten cap screw and lock nut
with two wrenches.
80 or less 3.8 hrs
@
7.5 hrs 11.3 hrs 15 hrs
@ @ @
3 amps 3 amps 3 amps
3
amps
Charging
81
to 125 5.3 hrs 10.5 hrs 15.8 hrs 21 hrs
@
amps
@ @ @
4 amps 4 amps 4 amps
To minimize possible damage to the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished with a constant current battery charger
which is available in most shops.
4
126
170
to
to
5.5 hrs
@
amps
11 hrs
@
16.5 hrs 22 hrs
@ @
5
5 amps 5 amps 5 amps
171
5.8 hrs 11.5 hrs 17.3 hrs 23 hrs
250
@
amps
@ @ @
6 amps 6 amps 6 amps
6
CAUTION
above
250
6 hrs
@
12 hrs
@
18 hrs
@
24 hrs
@
Follow the manufacturer’s instructions when us-
ing a battery charger.
10 amps 10 amps 10 amps 10 amps
CAUTION
NOTE: Using specific gravity of the battery cells is the
most accurate method of determining battery condition.
Do not charge a frozen battery because it can ex-
plode and cause injury. Let the battery warm to
60
1.
open specific gravity or circuit voltage.
Determine the battery charge level from either its
oF (15.5oC) before connecting to a charger.
Charge the battery in a well−ventilated place to
dissipate gases produced from charging. These
gases are explosive; keep open flame and elec-
trical spark away from the battery. Do not smoke.
Nausea may result if the gases are inhaled. Un-
plug the charger from the electrical outlet before
connecting or disconnecting the charger leads
from the battery posts.
Battery Charge
Level
Specific
Gravity
Open Circuit
Voltage
100%
75%
50%
25%
0%
1.265
1.225
1.190
1.155
1.120
12.68
12.45
12.24
12.06
11.89
3.
Following the manufacturer’s instructions, con-
nect the charger cables to the battery. Make sure a good
connection is made.
2.
Determine the charging time and rate using the
manufacturer’s battery charger instructions or the
following table.
4.
Charge the battery following the manufacturer’s
instructions.
5.
electrolyte. If the temperature exceeds 125oF (51.6oC)
Occasionally check the temperature of the battery
or the electrolyte is violently gassing or spewing, the
charging rate must be lowered or temporarily stopped.
6.
Three hours prior to the end of the charging, mea-
sure the specific gravity of a battery cell once per hour.
The battery is fully charged when the cells are gassing
freely at a low charging rate and there is less than a
0.003
change in specific gravity for three consecutive
readings.
Electrical System (Rev. C)
Page 5 − 34
Reelmaster 4000−D
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro 4000 D, Toro 98958SL |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)