CONTINUES TO SHEET 2
CONTINUES TO SHEET 2
CONTINUES TO SHEET 2
WHEN THE PTO SWITCH IS MOVED TO THE ENGAGE POSITION, PTO SWITCH
TERMINALS 4 & 5 ARE MOMENTARILY CONNECTED ALLOWING A CURRENT
PATH TO ENERGIZE THE PTO RELAY, THE DECK POSITION SWITCHES AND
THE PTO SOLENOIDS. DIODES D1--B, D1--C AND D1--D WILL THEN CREATE
A LATCHING CIRCUIT TO KEEP THE PTO RELAY ENERGIZED WHEN THE PTO
SWITCH IS IN THE ON POSITION.
(OPTIONAL CRUISE
CONTROL KIT)
(OPTIONAL CRUISE
CONTROL KIT)
(OPTIONAL CRUISE
CONTROL KIT)
(OPTIONAL CRUISE
CONTROL KIT)
(OPTIONAL CRUISE
CONTROL KIT)
FRONT DECK
PTO SOLENOID
(
IGNITION SWITCH IN RUN)
(DISENGAGED)
(DECK LOWERED)
(NOT IN NEUTRAL)
LEFT DECK
PTO SOLENOID
2WD SOLENOID
(DECK LOWERED)
RIGHT DECK
PTO SOLENOID
(OCCUPIED)
(IN 4WD)
(DECK LOWERED)
PTO OVERTEMP
SHUTDOWN RELAY
SOLENOID
CONTINUES TO SHEET 2
Groundsmaster 4000--D
Run (Mow) Circuits
Power Current
Control Current
Indication Current
Page 9 - 9