Battery Service
The battery is the heart of the electrical system. With
regular andproper service, battery lifecan beextended.
Additionally, battery and electrical component failure
can be prevented.
2
1
CAUTION
1
When working with batteries, use extreme cau-
tion to avoid splashing or spilling electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes. Always wear safety goggles and a face
shield when working with batteries.
Figure 30
1.
Knob
2.
Battery cover
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80oF (26.7oC)
Discharged: less than 1.240
Battery Specifications
BCI Group Size 55:
585
CCA at 0o F (--17.8o C)
Reserve Capacity of 95 minutes at 80oF (26.7oC)
2
1
Dimensions (including terminal posts and caps)
Length
Width
Height
9.05 inches (22.99 cm)
6.03 inches (15.31 cm)
8.50 inches (21.58 cm)
Removal (Fig. 30 and 31)
IMPORTANT: Be careful not to damage terminal
posts or cable connectors when removing the bat-
tery cables.
Figure 31
2.
1.
Ground cable
Positive cable
1.
tery retainer securing the back of the battery to the bat-
tery support.
Remove battery cover from the frame. Loosen bat-
IMPORTANT: Before cleaning the battery, tape or
block vent holes to the filler caps and make sure the
caps are on tightly.
2.
Loosen nut on ground cable (--) first and remove
C. Check for signs of wetness or leakage on the top
ofthe battery which mightindicate aloose ormissing
filler cap, overcharging, loose terminal post or over-
filling. Also, check battery case for dirt and oil. Clean
the battery with a solution of baking soda and water,
then rinse it with clean water.
ground cable from battery.This should prevent shortcir-
cuiting the battery, other components or the operators
hands.
3.
cable from battery.
Loosennutonpositivecable(+)andremovepositive
D. Check thatthe cover seal is notbroken away.Re-
place the battery if the seal is broken or leaking.
4.
5.
Make sure battery vent caps are on tightly.
Remove battery from the battery compartment to a
E. Check theelectrolyte levelineachcell.Ifthelevel
is below the tops of the plates in any cell, fill all cells
withdistilledwaterbetween theminimumandmaxi-
mum fill lines. Charge at 15 to 25 amps for 15 min-
utes to allow sufficient mixing of the electrolyte.
service area to allow better access for service.
Inspection, Maintenance and Testing
1.
Perform the following inspections and maintenance:
A. Check for cracks. Replace battery if cracked or
leaking.
B. Check battery terminal posts for corrosion. Use
wire brush to clean corrosion from posts.
Groundsmaster 3505--D
Page 5 -- 23
Electrical System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 3505 D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)