6.
Connect a digital multimeter (set to amps) between
Battery
Reserve
Capacity
(Minutes)
Battery Charge Level
the negative (--) battery post and the negative (--)
(ground) cable connector. The reading should be less
than0.1amp.Ifthereadingis0.1ampormore,theunit’s
electrical system should be tested and repaired.
(Percent of Fully Charged)
75%
50%
25%
0%
80
or less 3.8 hrs
@
7.5 hrs 11.3 hrs 15 hrs
@ @ @
3 amps 3 amps 3 amps
7.
thenegative(--)batterypost.Tightencapscrewandlock
nut with two wrenches.
Connect negative (--) (ground) cable connector to
3
amps
81
to 125 5.3 hrs 10.5 hrs 15.8 hrs 21 hrs
@
@ @ @
4 amps 4 amps 4 amps
4
amps
8.
107--0392)
and cable connectors to reduce corrosion after connec-
tions are made.
Apply battery terminal protector (Toro Part No.
or a light coat of grease on all battery posts
126
to
5.5 hrs
@
11 hrs
@
16.5 hrs 22 hrs
@ @
170
5 amps 5 amps 5 amps 5 amps
171
to
5.8 hrs 11.5 hrs 17.3 hrs 23 hrs
Charging
250
@
@ @ @
6 amps 6 amps 6 amps
6
amps
To minimize possible damage to the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished with a constant current battery charger
which is available in most shops.
above
250
6 hrs
@
12 hrs
@
18 hrs
@
24 hrs
@
10
amps 10 amps 10 amps 10 amps
CAUTION
CAUTION
Do not charge a frozen battery because it can ex-
plode and cause injury. Let the battery warm to
Follow the manufacturer’s instructions when us-
ing a battery charger.
60
oF (15.5o C) before connecting to a charger.
Charge the battery in a well--ventilated place to
dissipate gases produced from charging. These
gases are explosive; keep open flame and elec-
trical spark away from the battery. Do not smoke.
Nausea may result if the gases are inhaled. Un-
plug the charger from the electrical outlet before
connecting or disconnecting the charger leads
from the battery posts.
NOTE: Using specific gravity of the battery cells is the
most accurate method of determining battery condition.
1.
specific gravity or open circuit voltage.
Determine the battery charge level from either its
Battery Charge
Level
Specific
Gravity
Open Circuit
Voltage
3.
Following the manufacturer’s instructions, con-
nect thecharger cables to thebattery.Makesure agood
connection is made.
100%
75%
50%
25%
0%
1.265
1.225
1.190
1.155
1.120
12.68
12.45
12.24
12.06
11.89
4.
Charge the battery following the manufacturer’s
instructions.
5.
Occasionally check the temperature of the battery
2.
manufacturer’s battery charger instructions or the
Determine the charging time and rate using the
electrolyte. If the temperature exceeds 125oF (51.6oC)
or the electrolyte is violently gassing or spewing, the
charging rate must be lowered or temporarily stopped.
following table:
6.
Three hours prior to the end of the charging, mea-
sure the specific gravity of a battery cell once per hour.
The battery is fully charged when the cells are gassing
freely at a low charging rate and there is less than a
0.003
change in specific gravity for three consecutive
readings.
Groundsmaster 3505--D
Page 5 -- 25
Electrical System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 3505 D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)