Toro 05145SL Rev B Groundsmaster 3505 D Service Manual

Cutting Unit Circuit
Mow
Cutting Unit Blade Braking
Atwosectiongearpumpisdirectlycoupledtothethehy-
drostat which is driven by the engine. Gear pump sec-
tion  (P1) supplies  oil  flow  to the  cutting  unit  circuit
through the manifold block and to  the cutting unit mo-
tors.
When the solenoid valve  (R1) is de--energized as the
PTO  switch is  DISENGAGED,  brake relief  cartridge
(BV) shifts  to its closed  position, blocking return  flow
from the deck motors and slowing the cutting blades
Theinertiaoftherotatingcuttingblades,however,effec-
tively turns the deck motors into pumps causing an in-
crease in pressure as the flow from the motors comes
up against the closed brake relief cartridge (BV). When
this pressure  builds to  approximately 1500  PSI (103
bar), brake relief cartridge (BV) opens which allows hy-
draulic flow to return to  tank and reduces return pres-
sure. When return pressure drops below 1500 PSI (103
bar), brake relief cartridge (BV) reseats to further slow
the cutting blades. This action repeats several times in
a very short time frame as the blades finally come to a
stop. Once the blades  have stopped, brake relief car-
tridge (BV)  remains seated  to keep  the deck motors
from rotating.
Solenoid valve (R1)  in the manifold block is de--ener-
gized when either the PTO switch is in DISENGAGE or
the transport/mow slide is in TRANSPORT. When de--
energized, solenoid valve (R1) by--passes flow from the
cutting unitmotors.Flowreturnstogearpump(P1)inlet.
Solenoid valve (R1) is energized when the PTO switch
is in ENGAGE and the transport/mow slide is in MOW.
When energized, solenoid valve (R1) allows gear pump
(P1) flow out manifold block port M1 to the cutting unit
motors. When solenoid valve (R1) is energized, brake
relief cartridge (BV) is shifted (opens) to allow oil return
from the cutting unit motors.
Oil flows through the left, right and then rear cutting unit
motors  as it  turns  the  motors. The  oil  then  returns
through manifold block port (M2), the oil cooler, the oil
filter and to gear pump (P1) inlet.
If cutting unit circuit pressure exceeds relief pressure of
3200
PSI (221 bar), solenoid valve (R1) shifts to allow
circuit pressure relief.
Groundsmaster 3505--D
Page 4 -- 11    Rev. B
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 210 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website