Charging
CAUTION
To minimize possible damage to  the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished  with  a  constant  current  battery  charger
which is commonly available.
Do not charge a frozen battery because it can ex-
plode and cause injury. Let  the battery warm to
o
F (15.5  C) before  connecting to a charger.
60
o
Charge the battery in  a well–ventilated place to
dissipate gases produced from charging. These
gases are explosive; keep open flame and elec-
trical spark away from the battery. Do not smoke.
Nausea may result if the gases  are inhaled. Un-
plug the charger from the electrical outlet before
connecting or  disconnecting the charger leads
from the battery posts.
CAUTION
Follow  the  battery charger  manufacturer’s  in-
structions when using a battery charger.
NOTE:  Using specific gravity of the battery cells is the
most accurate method of determining battery condition.
3.
Following the battery charger manufacturer’s in-
structions, connect the  charger cables to the  battery
terminals. Make sure a good connection is made.
1.
Determine the  battery charge  level from  either its
specific gravity or open circuit voltage.
4.
manufacturer’s instructions.
Charge the battery following  the battery charger
Battery Charge
Level
Specific
Gravity
Open Circuit
Voltage
5.
Occasionally check  the temperature of  the battery
100%
75%
50%
25%
0%
1.265
1.225
1.190
1.155
1.120
12.68
12.45
12.24
12.06
11.89
electrolyte. If the temperature exceeds 125oF (51.6oC)
or the  electrolyte is  violently gassing or  spewing, the
charging rate must be lowered or temporarily stopped.
6.
Three  hours prior  to the  end  of battery  charging,
measure the specific gravity  of a battery cell once per
hour. The battery is fully charged when the cells are gas-
sing freely at a low charging rate and there is less than
a 0.003 change in specific gravity for three consecutive
readings.
2.
Determine the charging time and rate using the bat-
tery charger manufacturer’s instructions or  the fol-
lowing table.
NOTE:  The reserve  capacity  of  the  battery used  in
Sand Pro and Infield Pro machines is 28 minutes.
Battery
Reserve
Capacity
(Minutes)
Battery Charge Level
(Percent of Fully Charged)
75%
50%
25%
0%
80
or less    3.8 hrs
@
7.5 hrs     11.3 hrs     15 hrs
@             @             @
3 amps     3 amps     3 amps
3
amps
81
to 125     5.3 hrs     10.5 hrs   15.8 hrs      21 hrs
@
@             @             @
4 amps     4 amps     4 amps
4
amps
126
to
to
5.5 hrs
@
11 hrs
@
5 amps     5 amps     5 amps
16.5 hrs     22 hrs
170
@             @
5
amps
171
250
5.8 hrs     11.5 hrs    17.3 hrs     23 hrs
@
amps
@             @             @
6 amps     6 amps     6 amps
6
above
250
6 hrs
@
12 hrs
@
18 hrs
@
24 hrs
@
10
amps   10 amps   10 amps   10 amps
Sand Pro & Infield Pro 3040/5040                           Page 5 – 17
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 152 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower