Toro 10177SL Models 30449 30447 Groundsmaster 4100 4110 D Service Manual

Procedure  for  Engine  Cooling  Fan  Circuit  Gear
Pump Flow Test
7.  Move throttle so engine is running at high idle speed
(2870 RPM). DO NOT engage the cutting deck.
1.
Make sure hydraulic oil is at normal operating tem-
8.  While watching tester pressure gauge, slowly close
flow control valve until 1000 PSI (69 bar) is obtained on
pressure gauge. Verify  engine speed continues to  be
2870 RPM.
perature  by  operating  the  machine  under  load  for
approximately ten (10) minutes. Make sure the hydrau-
lic tank is full.
2.
lowered and off. Make sure engine is off and the parking
brake is applied. Raise and support seat.
Parkmachineonalevelsurfacewiththecuttingdeck
GAUGE READING  TO BE:  Flow approximately 7
GPM (26 LPM) at 1000 PSI (69 bar).
NOTE:  If engine speed drops below 2870 RPM during
testing, expect pump flow to decrease.
CAUTION
9.
Open the tester flow control valve and stop the en-
gine. Record test results.
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS and Pre-
cautions for Hydraulic Testing at the  beginning
of this section.
10.If
a pressure of 1000 PSI (69 bar) could not be ob-
tained or flow is lower than 6 GPM (23 LPM), check for
restriction in pump  intake line. If  intake line is not  re-
stricted, consider that gear pump is worn or damaged.
3.
hose at the last gear pump section which supplies the
engine cooling fan circuit (Fig. 50).
Thoroughly  clean junction  of fitting  and hydraulic
11.
nect hose to pump fitting.
When testing is complete, remove tester and recon-
4.
Withtheengineoffandcuttingdecklowered,discon-
nect the hydraulic  hose from the 90o fitting in  the last
gear pump section.
2
RIGHT
FRONT
IMPORTANT: Make sure  that the oil flow  indicator
arrow on the flow gauge is showing that the oil will
flow from the pump section, through the tester and
into the hydraulic hose.
1
4
5.
Install tester with pressure gauge and flow meter in
series between the fitting  and the disconnected hose.
Makesuretheflowcontrolvalveonthetesterisfully
open.
6.
speed. Check  for hydraulic leakage  at tester location
and correct before proceeding with test.
After installing  tester, start  engine and  run at idle
3
Figure 50
IMPORTANT: The pump is a positive displacement
type.  If   pump  flow  is  completely   restricted  or
stopped, damage to the pump, tester or other com-
ponents could occur.
1.
2.
Gear pump
Fan drive manifold
3.
4.
Cooling fan supply hose
90   fitting
o
Groundsmaster 4100--D/4110--D
Page 4 -- 69
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website