Toro 10177SL Models 30449 30447 Groundsmaster 4100 4110 D Service Manual

Engine Cooling Fan Switch
Theenginecoolingfanswitchisatwo(2)positionrocker
switch that is located on the outside of the control con-
sole (Fig. 30). The switch has a normal and a momen-
tary position.
6.  If switch tests correctly and  circuit problem still ex-
ists, check wire harness (see Electrical Schematics and
Wire Harness Drawings in Chapter 10 -- Foldout Draw-
ings).
The engine cooling fan switch is used as an input for the
TEC--5002 controller to allow the engine cooling fan to
run in the normal, automatic mode or in the manual re-
verse (momentary) direction.
7.  After  testing is  completed,  connect wire  harness
connector to the switch.
8.
Assemble console arm (see Console Arm Assembly
in the Service and Repairs section of Chapter 7 -- Chas-
sis).
Testing
1.
Before disconnecting the engine cooling fan switch
for testing,  the switch and  its circuit wiring should  be
tested as a TEC--5002 input with the Diagnostic Display
(see Diagnostic Display in the Troubleshooting section
of this chapter).  If the Diagnostic Display  verifies that
switch andcircuit wiring arefunctioning correctly,nofur-
ther switch testing is necessary. If, however, the Display
determines that  the switch and  circuit wiring  are not
functioning correctly, proceed with test.
1
2
2.
Make sure ignition switch is OFF. Remove key from
ignition switch.
3.
ing fan  switch (see Console  Arm Disassembly  in the
Service and Repairs section of Chapter 7 -- Chassis).
Disassemble console arm togain access to thecool-
Figure 30
4.
Disconnect wire harness  electrical connector from
1.
Console arm
2.   Cooling fan switch
the switch.
5.
With  the use  of a  multimeter  (ohms setting),  the
switch functions  may be tested to  determine whether
continuity exists between the various terminals for each
switch position.  The switch  terminals are  marked as
shown in  Figure  31. The  circuitry of  the  cooling fan
switch is shown in the chart below. Verify continuity be-
tween switch terminals.
BACK OF SWITCH
SWITCH
NORMAL
CIRCUITS
OTHER
POSITION
CIRCUITS
Figure 31
NORMAL
2 + 3
2 + 1
5 + 6
5 + 4
MOMENTARY
NOTE:  Only cooling fan switch terminals 1  and 2 are
used  on  Groundsmaster  4100--D  and  4110--D  ma-
chines.
Groundsmaster 4100--D/4110--D
Page 5 -- 27
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website