Toro 10177SL Models 30449 30447 Groundsmaster 4100 4110 D Service Manual

Battery Service
The battery is  the heart of the electrical  system. With
regular andproper service, battery lifecan beextended.
Additionally, battery  and  electrical component  failure
can be prevented.
2
1
CAUTION
When working with batteries, use  extreme cau-
tion to  avoid  splashing or  spilling electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes.  Always wear  safety goggles  and  a face
shield when working with batteries.
3
Electrolyte Specific Gravity
Figure 60
3.
Fully charged: 1.265 corrected to 80oF (27oC)
1.
2.
Negative (--) cable
Positive (+) cable
Battery strap
Discharged: less than 1.240
Battery Specifications
Battery Inspection, Maintenance and Testing
BCI group size 34
690
110
CCA at 0o F (--18o C)
minutes reserve capacity at 80oF (27oC)
1.
Perform following inspections and maintenance:
A.  Check for cracks. Replace battery if cracked  or
leaking.
Dimensions (including terminal posts and
caps)
Length   10.2 inches (259 mm)
B.  Check battery terminal posts for corrosion. Use
wire brush to clean corrosion from posts.
Width
6.6 inches (167 mm)
8.0 inches (203 mm)
Height
Battery Removal and Installation (Fig. 60)
IMPORTANT: Before  cleaning the  battery, tape
or block vent holes  to the filler caps and  make
sure the caps are on tightly.
1.
Raise and  support operator seat. Remove  battery
access panel.
C. Check for signs of wetness or leakage on the top
ofthe battery which mightindicate aloose ormissing
filler cap, overcharging, loose terminal post or over-
filling. Also, check battery case for dirt and oil. Clean
the battery with a solution of baking soda and water,
then rinse it with clean water.
2.
ter negative cable is removed, loosen and remove posi-
tive cable.
Loosen and remove negative cable from battery. Af-
3.
chine.
Loosen battery  strap  that secures  battery to  ma-
D. Check thatthe cover seal is notbroken away.Re-
place the battery if the seal is broken or leaking.
4.
Carefully remove battery from machine.
5.
nect and tighten  positive cable to  battery before con-
necting negative cable.
Install battery in reverse order making sure to con-
E.  Check theelectrolyte levelineachcell.Ifthelevel
is below the tops of the plates in any cell, fill all cells
withdistilledwaterbetween  theminimumandmaxi-
mum fill lines. Charge at 15 to 25 amps for 15 min-
utes to allow sufficient mixing of the electrolyte.
NOTE:  Before connecting the negative (ground) cable
to the battery,  connect a digital multimeter (set  to DC
Amps) between the negative battery post and the nega-
tive (ground) cable  connector. The reading should be
less than 0.1 amp. If the reading is 0.1 amp or more, the
machine’s electrical system should be tested for short
circuits or faulty components and repaired.
6.
cess panel. Lower and secure operator seat.
Secure battery with battery strap. Install battery ac-
Groundsmaster 4100--D/4110--D
Page 5 -- 45
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website