Removal (Fig. 6)
Park machine on a level surface, lower cutting
Installation (Fig. 6)
1.
1. Position condenser coil to roof.
decks, stop engine, engage parking brake and remove
key from the ignition switch.
2.
Remove caps that were placed on A/C hoses and fit-
tings during the removal process. Using labels placed
during removal, properly secure hoses to condenser
coil.
2.
Remove fasteners that secure roof in place. Raise
andsupportrooftoallowaccesstocondenserassembly
(see Roof Assembly Removal in this section).
3.
Position condenser mount to condenser coil.Secure
3.
Disconnect wire harness connector from condenser
mount with four (4) button head screws (item 5).
fan motor.
4.
Position condenser fan and cover to condenser fan
4.
denser fan and cover to condenser fan mount. Lift cover
and fan from roof.
Removefour(4)flangenuts(item2)thatsecurecon-
mount and secure with four (4) flange nuts (item 2).
5.
Connect wire harness connector to condenser fan
motor.
5.
cure condenser fan mount (item 12) to roof. Lift fan
mount from roof.
Remove four (4)button headscrews (item5) thatse-
6.
nents are installed and secure.
Make sure that all machine air conditioning compo-
7.
Have a certified air conditioning service technician
6.
Read the General Precautions for Removing and
evacuate the air conditioning system completely, prop-
erly recharge the system with R134a refrigerant and
then leak test the system. A/C system capacity is
approximately 1 pound 6 ounces (624 gm) of R134a re-
frigerant.
Installing Air Conditioning System Components at the
beginning of the Service and Repairs section of this
chapter.
CAUTION
8.
Lower and secure roof assembly (see Roof Assem-
bly Installation in this section).
The air conditioning system is under high pres-
sure. Do not loosen any system fitting or compo-
nent until after the system has been completely
discharged by a certified A/C service technician.
7.
system by a certified A/C service technician.
Have refrigerant evacuated from air conditioning
8.
Immediately cap hoses and fittings to prevent moisture
and contaminants from entering the system.
Label and remove A/C hoses from condenser coil.
9.
Remove condenser coil from roof.
NOTE: Thereplacementofthedrier--receiverisrecom-
mended whenever the air conditioning system is
opened (see Heater/Evaporator Assembly in this sec-
tion).
Groundsmaster 4110--D
Page 9 -- 11
Operator Cab
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 10177SL, Toro Groundsmaster 30447, Toro Groundsmaster 30449, Toro Groundsmaster 4100, Toro Groundsmaster 4110 D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |