Electrical System Quick Checks
Battery Test
Use a multimeter to measure the voltage between the
battery terminals.
Voltage Measured
Battery Charge Level
Fully charged (100%)
75% charged
12.68
12.45
12.24
12.06
11.89
V (or higher)
Set the multimeter to the DC volts setting. The battery
should be at a temperature of 60 to 100 F. The ignition
o o
key should be off and all accessories turned off. Connect
the positive (+) meter lead to the positive battery post
and the negative (–) meter lead the the negative battery
post.
V
V
V
V
50% charged
25% charged
0% charged
NOTE: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.