Rework Starter/Generator (Fig. 22)
NOTE: Rework to the starter/generator must be per-
formed by a properly trained technician using the correct
tools and equipment for testing and reworking electrical
motors and generators. It may be more economically
feasible to replace the starter/generator than have it re-
worked.
Detail
Minimum commutator diameter
Commutator concentricity to the shaft
Commutator machining limit per cut
Insulator depth between commutator bars
Armature insulation resistance
Dielectric (insulation strength)
Starter field coil resistance
Specification
1.575 inches (40mm)
0.0003 inch (0.008 mm)
0.005 inch (0.127 mm)
0.020 inch (0.5 mm)
0.2 Mohm at 500 VDC
500 VDC for one minute with no insulation break down
o o
2.38 to 2.44 ohms at 20 C (68 F)
Generator field coil resistance
o o
0.041 ohm for F1 and 0.043 ohm for F2 at 20 C (68 F)
Electrical System
Page 6 – 22
Workman 1100/1110/2100/2110
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Workman 1100, Toro Workman 1110, Toro Workman 2100, Toro Workman 2110 |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |