Lower Reels Time Delay
This is a solid state timer used to energize solenoid
valve S4 long enough to fully retract the cutting unit lift
cylinders, making sure the cutting units are fully lower-
ed. Upon the application of power, the load is energized
and the time delay is started. After 6 seconds the load
is de--energized.
+
--
INPUT VOLTAGE
1.
Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After 6 seconds, there should
be no voltage across the load.
LOAD
2.
Disconnect timer from 12VDC source and test load.
3
2
1
TIMING
RESISTOR
4
5
TIME
DELAY
Figure 21
Figure 20
Leak Detector Alarm and Delay Timer
Toprevent the leakdetector system from sounding false
alarms during normal operation. the alarm circuit in-
cludes a one second delay timer.
1.
then move leak detector test switch rearward and hold.
After a one second time delay the alarm should sound.
Turn ignition switch to On (do not start the engine),
2
1
Figure 22
1.
Alarm
2.
Delay timer
Greensmaster 3150
Page 5 -- 15
Electrical System
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Greensmaster 3150 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
Safety switches not working