GREENSMASTER® 1000 Maintenance Schedule
Minimum Recommended Maintenance Intervals:
Maintenance Procedure
Maintenance Interval & Service
Every
200hrs
Every
100hrs
Every
50hrs
Service Air Filter Pre-Cleaner
Lubricate All Grease Fittings
Check for loose Fasteners
Clean Fuel Filter and Sediment Bowl
Adjust Traction Drive Belts
Change Engine Oil
Every
25hrs
A Level
B Level
Service
†
1
Clean Combustion Chamber
Replace Spark Plug
1
Check Cut-Off Bar Adjustment
Service Air Cleaner Filter
Clean Combustion Chamber
Replace Spark Plug
C Level
Service
2
2
D Level
Service
Adjust Valves and Torque Head Bolts
†
Initial Break in at 20 hours
1
Interval for Engine Model: FG150
Interval for Engine Model: FE120
2
Annual Recommendations:
Item listed is recommended every 2 years.
Replace All Interlock Switches
(See Operator's and Service Manual for specifications and procedures)