Toro 01088SL Rev F Service Manual Groundsmaster 3500 D Preface Publication

Glow Relay
The glow  relay is  attached to  the radiator  assembly.
Whenenergized, theglow relay allows electrical current
to the engine glow plugs.
87
86
85
87
30
Two  styles  of  glow relays  have  been  used  on  the
Groundsmaster 3500--D. On machines with serial num-
bers below 240000000,  two of the four  relay connec-
tionsaresecuredwithscrews(Fig.7).Onmachineswith
serial numbers above 240000000, the glow relay is at-
tached to the wire  harness with a four wire connector
(Fig. 8).
30
85
86
Figure 7
1.
Verify coil resistance between terminals 86  and 85
with a multimeter (ohms setting).
A.  On   machines   with   serial    numbers   below
86
87
30
240000000,
ohms.
resistance  should be  from  41  to 51
85
86
B.  On   machines   with   serial   numbers    above
85
30
87
240000000,
ohms.
resistance should be approximately 72
2.
Connectmultimeter (ohmssetting) leadstorelayter-
Figure 8
minals 30 and  87. Ground terminal 86 and  apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
3.
Disconnect voltage and leads from the terminals.
Interlock, Neutral, Seat, and High Temperature Shutdown Relays
These relays  are located in the  control panel on  ma-
chines with Serial Numbers below 240000000.
86
87A
87
87
1.
Verify coil resistance between terminals 86  and 85
87A
with a multimeter (ohms setting). Resistance should be
from80to90ohms.Thereshouldbecontinuity     between
terminals 87A and 30.
86
85
30
2.
Connectmultimeter (ohmssetting) leadstorelayter-
85
30
minals 30 and  87. Ground terminal 86 and  apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
3.
lead from terminal 87.
Disconnect voltage from terminal 85 and multimeter
TOP VIEW
4.
Connectmultimeter (ohmssetting) leadstorelayter-
minals 30 and 87A. Apply +12 VDC to terminal 85. The
relay should make and break continuity between termi-
nals 30 and 87A as +12  VDC is applied and removed
from terminal 85.
Figure 9
5.
Disconnect voltage  and multimeter leads from  the
relay terminals.
Electrical System (Rev. D)
Page 5 -- 10   Rev. E
Groundsmaster 3500--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 256 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website