Procedure for Cutting Deck Circuit Pressure Test:
Make sure hydraulic oil is at normal operating tem-
1.
perature by operating the machine for approximately 10
minutes.
1
2.
lowered and off. Make sure engine is off and the parking
brake is engaged.
Parkmachineonalevelsurfacewiththecuttingunits
2
3.
4.
5.
Read Precautions for Hydraulic Testing.
Remove plug from hydraulic manifold port (G1).
Install test gauge with hydraulic hose attached to the
Figure 23
manifold port (G1).
1.
Hydraulic manifold
2.
Manifold port (G1)
CAUTION
Keepawayfromdecksduringtesttopreventper-
sonal injury from the cutting blades.
1
6.
50
Start engine and move throttle to full speed (3050 +
RPM). Engage the cutting units.
7.
Watch pressure gauge carefully while mowing with
the machine.
8.
PSI and will vary depending on mowing conditions.
Cutting circuit pressure should be from 1000 to1500
2
9.
Disengage cutting units. Shut off engine.
test gauge with hose from manifold
10.Disconnect
Figure 24
2.
block. Reconnect plug to the hydraulic manifold port
(G1).
1.
Hydraulic manifold
Manifold port (G1)
Groundsmaster 3500--D
Page 4 -- 41
Hydraulic System (Rev. D)
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 3500 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |