Removal (Fig. 78)
75
(101 N--m)
ft--lb
75
(101 N--m)
ft--lb
50
(68
ft--lb
N--m)
NOTE:  The ports on the manifold are marked for easy
identification of components. Example:  P1 is the gear
pump  connection port  (see Hydraulic  Schematics  in
Chapter 9 -- Foldout Drawings to identify the function of
the hydraulic lines and cartridge valves at each port).
1
2
3
4
5
6
7
1.
decks, stop  engine, apply parking  brake and remove
key from the ignition switch.
Park  machine  on  a  level  surface,  lower  cutting
11
2.
Installing Hydraulic System Components at the begin-
ning of the Service and Repairs section of this chapter.
Read the  General Precautions  for Removing  and
14
13
15
11
10
12
9
3.
4.
Unlatch and raise hood.
8
17
13
To prevent contamination of hydraulic system during
16
GM 4500--D
manifold removal, thoroughly clean exterior ofmanifold.
5.
to manifold solenoid coils. Disconnect connectors from
the solenoid coils.
Label wire harness electrical connectors that attach
Figure 79
1.
2.
3.
4.
5.
6.
7.
8.
9.
Deck manifold
O--ring
10. O--ring
11. O--ring
Straight fitting (8 used)
O--ring
12. 45o fitting
6.
caps or plugs on open hydraulic lines and fittings. Label
disconnected hydraulic lines for proper assembly.
Disconnect hydraulic  lines  from manifold  and put
13. O--ring
O--ring
Straight fitting
O--ring
Dust cover
Test fitting
14. Straight fitting
15. O--ring
16. 90o fitting
17. O--ring
7.
Remove hydraulic  manifold  from the  frame using
Figure 78 as guide.
8.
If hydraulic fittings  are to be removed from  control
75 ft--lb
(101 N--m)
75 ft--lb
(101 N--m)
manifold,markfittingorientation  toallowcorrectassem-
bly (Fig. 79 or 80). Remove  fittings from manifold and
discard O--rings.
1
8
9
10
Installation (Fig. 78)
2
3
1.
If fittings were removed from control manifold, lubri-
4
cate and place new O--rings onto fittings. Install fittings
into manifold ports using marks made during theremov-
al process to properly orientate fittings. Tighten fittings
(see Hydraulic Fitting Installation in  the General Infor-
mation section of this chapter). Refer to Figure 79 or 80
for fitting installation torque.
7
6
11
12
5
11
17
2.
78
Install hydraulic manifold to the frame using Figure
as guide.
50
(68
ft--lb
N--m)
13
13
14
15
3.
Remove caps  and  plugs from  fittings and  hoses.
GM 4700--D
16
Properly connect hydraulic  lines to manifold (see  Hy-
draulic Hose and Tube Installation in the General Infor-
mation section of this chapter).
Figure 80
1.
2.
3.
4.
5.
6.
7.
8.
9.
Deck manifold
O--ring
Test fitting
Dust cap
O--ring
Straight fitting
O--ring
O--ring
10. O--ring
11. O--ring
4.
solenoid valve coils.
Connect wire  harness electrical connectors  to the
12. Straight fitting
13. O--ring
14. O--ring
5.
Lower and secure hood.
15. O--ring
16. 90o fitting
17. 45o fitting
Straight fitting (8 used)
Groundsmaster 4500--D/4700--D
Page 4 -- 97
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 298 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website