Toro 09172SL Models 30857 30858 Groundsmaster 4500 D 4700 D Service Manual

Hydraulic Solenoid Valve Coils
Numerous hydraulic solenoid  valve coils are  used on
the  hydraulic   control  manifolds   of  Groundsmaster
5.  If solenoid coil resistance is incorrect, replace sole-
noid (see Hydraulic Solenoid Valve  Coil Removal and
Installation in the  Service and Repairs  section of this
chapter).
4500--D
and 4700--D machines. When energized by the
TEC controller, these coils provide hydraulic circuit con-
trol.
6.
After  testing is  completed,  connect wire  harness
Two (2) different solenoid  valve coils are used on  the
connector to the solenoid.
4500--D
and4700--D.Acoilcanbeidentifiedbymeasur-
ing it’s height and diameter (Fig. 38). Testing of the coils
can be  done with the coil  remaining on the  hydraulic
valve.
NOTE:  To assist in troubleshooting, identical solenoid
coils can be exchanged. If the problem follows the ex-
changed coil, a problem with the coil likely exists. If the
problem remains unchanged, something other than the
solenoid coil is the problem source (e.g. switch, circuit
wiring, hydraulic problem).
COIL
DIAMETER
Testing
1.
decks, stop engine, engage parking brake and remove
key from the ignition switch.
Park  machine  on  a  level  surface,  lower  cutting
2.
Identify coil  by  measuring the  coil diameter  and coil
height (Fig. 38).
Locate hydraulic  valve solenoid  coil to  be tested.
COIL
HEIGHT
3.
Disconnect wire harness connector from coil.
NOTE:  Prior to taking small resistance readings with a
digital multimeter, short the  meter test leads together.
The meter will display a small resistance value (usually
0.5
ohms or less). This resistance is due to the internal
Figure 38
resistance of the meter and test leads. Subtract this val-
ue from from the measured value of the component you
are testing.
4.
Using a multimeter (ohms  setting), measure resis-
tance between the two (2)  connector terminals on the
solenoid valve coil. The correct resistance for the sole-
noid coil is identified below:
COIL
DIAMETER
COIL
HEIGHT
COIL
RESISTANCE
1.84
in
1.96 in
(49.9 mm)
7.1 ohm
(46.7
mm)
1.41
in
1.43 in
(35.8 mm)
8.8 ohm
(35.8
mm)
NOTE:  Solenoid coil resistance  should be measured
with solenoid atapproximately 68oF(20oC).Resistance
may be slightly different than listed at different tempera-
tures.  Typically,  a failed  solenoid  coil  will  either be
shorted (very low or no resistance) or open (infinite re-
sistance).
Electrical System
Page 5 -- 28
Groundsmaster 4500--D/4700--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 298 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website