Toro 09172SL Models 30857 30858 Groundsmaster 4500 D 4700 D Service Manual

Fuses
Groundsmaster  4500--D and  4700--D use  numerous
fuses for circuit protection. The fuses are located in two
Fuse Testing
Make sure that ignition switch is OFF and key is re-
1.
(2)
areas of the machine. Most of the fuses reside in the
moved from switch.
power center behind the operator’s seat. An in--linefuse
holder located in the wire harness near the engine start-
er motor holds an additional  fuse (F5--1) that protects
the engine run solenoid circuit.
2.
Remove power center cover from operator platform
to access fuses.
3.
should have continuity across the terminals.
Remove  fuse  from  fuse  block  for  testing.  Fuse
Fuse Identification and Function (Figs. 14 and 15)
Fuse F1--1 (20 Amp) supplies power  to engine starter
circuit.
4.
power center cover.
After fuse  testing is completed,  install and secure
Fuse F1--2position available for optionalflow divider kit.
Fuse F1--3 position available for optional kit.
Fuse F1--4 position available for optional kit.
20A
Fuse F2--1 (10 Amp) supplies power to the light circuit.
FuseF2--2(10Amp)suppliespowertotheoperatorseat
circuit.
10A
10A
10A    10A
Fuse F2--3 (10 Amp) supplies power to the powerpoint.
GM4500
TEC--5002
Fuse F2--4 (10 Amp) supplies power to the main power
circuit.
2A
7.5A   7.5A   7.5A
Fuse  F3--1   (2  Amp)  supplies   logic  power  to   the
TEC--5002 controller.
GM4700
TEC--5001
2A
7.5A   7.5A   7.5A    60A
Fuse F3--2 (7.5 Amp) supplies power to the TEC--5002
controller.
Figure 14
Fuse F3--3 (7.5 Amp) supplies power to the TEC--5002
controller.
FRONT
Fuse F3--4 (7.5 Amp) supplies power to the TEC--5002
controller.
F1
Fuse  F4--1   (2  Amp)  supplies   logic  power  to   the
TEC--5001 controller.
F2
F3
Fuse F4--2 (7.5 Amp) supplies power to the TEC--5001
controller.
Fuse F4--3 (7.5 Amp) supplies power to the TEC--5001
controller.
M2 (option)
M1 (60A)
Fuse F4--4 (7.5 Amp) supplies power to the TEC--5001
controller.
F4
Fuse M1 (60A) supplies power to the glow plug circuit.
Fuse M2 position available for operator cab option.
1
2
3
4
Figure 15
Fuse F5--1 (in--line 40A) supplies power for the engine
run solenoid.
Electrical System
Page 5 -- 16
Groundsmaster 4500--D/4700--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 298 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website