Toro 09172SL Models 30857 30858 Groundsmaster 4500 D 4700 D Service Manual

Mow Circuit
Hydraulic flow for the mow circuit is supplied by two (2)
sections of the gear pump (P1 and P2). Gear pump sec-
tion P1 supplies hydraulic flow to decks 5, 3 and 2 (also
deck 7 on the GM 4700--D), while gear pump section P2
supplies decks1and4(alsodeck6ontheGM4700--D).
#4 Deck
#1 Deck
#5 Deck
A single deck  control manifold is used  to control flow
from the two (2) pump sections. The manifold includes
cartridge valves for control of each of the two (2) pump
circuits. Each manifold circuit is equipped  with a sole-
noid controlled, proportional relief valve (PRV1/PRV2),
a logic cartridge (LC1/LC2) and a brake relief cartridge
(RV8/RV9).TheGroundsmaster  4700--Ddeck manifold
includes additional cartridges to  control hydraulic flow
for  decks   6  and   7:  an   additional  logic   cartridge
(LC3/LC4),asolenoidvalve(SV1/SV2)andanaddition-
al brake relief cartridge (RV10/RV11).
#2
Deck
#3
Deck
#
6 Deck
#7 Deck
(GM4700)
(GM4700)
CUTTING DECK LOCATIONS
PTO Disengaged
Figure 18
When the PTOswitch isOFF (orifthedecks  areraised),
the manifold solenoid valves (PRV1 and PRV2) are not
energized, allowing hydraulic flow  to bypass the deck
motors through the manifold. Return oil from the man-
ifolds is directed to the oil cooler and oil filter.
DECK CONTROL MANIFOLD
(Groundsmaster 4700--D)
FROM
DECK 7
PTO Engaged
When the PTO switch is turned ON with the decks low-
ered, the solenoid valves (PRV1 and PRV2) are ener-
gized with outputs from the  TEC--5002 controller. The
energized valves shift  to direct pump  flow toward the
deck motors. As circuit pressure to the deck motors in-
creases, the brake relief cartridge (RV) opens which al-
lows an oil flow through the manifold orifice positioned
before the logic cartridge (LC). This flow creates a pres-
sureincrease atthelogic  cartridge that willshift thelogic
cartridge and allow oil return from the deck motors.
TO  DECK
7
FROM
DECKS
2, 3 & 5
FROM
PUMP P1
TO  DECKS
2,
3 & 5
FROM
DECK 6
TO  DECK
6
On the Groundsmaster 4700--D  (Fig. 19), if deck 6 or
deck 7 is lowered and the PTO switch is ON, the deck
control manifold solenoid valve (SV1/SV2) will be ener-
gized by the TEC--5001 controller. This energized sole-
noid valve allows oil flow to the appropriate deck motor
as described above.
FROM
DECKS
1
& 4
FROM
PUMP P2
TO  DECKS
1 & 4
TO  OIL
COOLER
Maximum mow circuit pressure is limited at each deck
manifold   circuit   by   the   proportional   relief   valve
(PRV1/PRV2). The deck relief  valve pressure is 3500
PSI (241 bar). Mow circuit pressure can be measured at
port G1 or G3 of the deck control manifold.
PTO SWITCH ON AND
(RH) DECK RAISED
#7
Figure 19
Thebrakereliefandlogiccartridgescontrolthestopping
rate of the blades when the solenoid valves are de--en-
ergized as the PTO switch is turned OFF or if the decks
are raised (see Cutting Deck Blade Braking in this sec-
tion).
Groundsmaster 4500--D/4700--D
Page 4 -- 25
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 298 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower