Engine Cooling Fan Circuit Problems
Problem
Possible Cause
Cooling fan runs only in forward di-
rection (fan does not run in reverse
direction).
Fan control manifold solenoid cartridge valve (S1) is faulty.
Electrical problem exists that prevents fan control manifold solenoid
valve (S1) operation (see Chapter 5 -- Electrical System).
Cooling fan does not rotate.
Fan motor is worn or damaged.
Gear pump section (P4) is worn or damaged.
Cooling fan always rotates at slow
speed.
Fan control manifold cartridge valve seals are leaking.
Check valve in fan control manifold is not seating.
Fan control manifold proportional relief valve (TS) is stuck open.
Hydraulic fan motor is worn or damaged.
Cooling fan always rotates at fast
speed.
Fan control manifold proportional relief valve (TS) is faulty.
Electrical problem exists that prevents fan control manifold propor-
tional relief valve (TS) operation (see Chapter 5 -- Electrical Sys-
tem).
Hydraulic System
Page 4 -- 40
Groundsmaster 4500--D/4700--D
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 30857, Toro Groundsmaster 30858, Toro Groundsmaster 4500 D, Toro Groundsmaster 4700 D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |