Toro 99024SL Rev E Reelmaster 3100 D Preface Publication Service Manual

Glow Controller
The controller is located under the right lower corner of
the instrument panel.
2
Note:
Refer to Electrical Schematics and Diagrams at
the beginning of the chapter when troubleshooting  the
controller.
3
6
2
1
5
4
Controller Operation
1.
When the ignition switch is placed in the RUN posi-
tion, the controller energizes the glow  plugs and lights
up the glow lamp for 10 seconds.
1
Note:
90150,
On  units with  serial  numbers from  90101  to
the glow controller is not in use when the ignition
switch is turned to start.
3
2.
tion, the glow plugs will energize while the switch is held
in START and the glow lamp will not light.
When the ignition switch is held in the START posi-
Figure 24
1.
2.
Glow controller end view
Top view
3.
Side view
3.
RUN, the glow plugs will deenergize and the glow lamp
will remain off.
When the ignition switch is released from START to
4.
the following while in the START position:
Place ignition  switch in the START  position. Verify
A.  Glow indicator lamp is out.
Controller Checks
B.  Glow relay is energized.
1.
Make sure there is power from the battery.
C. Glow plugs are energized.
2.
Disconnect electrical connector to the  run solenoid
to prevent the engine from starting.
D. Power to terminal 1 of the glow controller.
3.
Place ignition switch in the RUN position. Verify the
5.
to terminal 1  exists and any of  the other conditions in
step 4 are not met:
If any of the conditions in step 3 are not met or power
following while in the RUN position:
A.  Glow indicator lamp is on.
B.  Glow relay is energized.
A.  Verify continuity of the circuitry from the battery to
the glow relay and glow plugs (see Electrical Sche-
matics and Diagrams in this chapter).
C. Glow plugs are energized.
B.  Verify continuity of the circuitry from the battery to
ignition  switch,  glow  controller,  glow  lamp,  glow
relay, and  ground  (see Electrical  Schematics and
Diagrams in this chapter).
D. Glow  indicator  lamp  goes out  and  glow plugs
deenergize after 10 seconds.
Note:
90150,
On  units with  serial  numbers from  90101  to
the glow controller is not in use when the ignition
C. Replace parts as necessary.
switch is turned to start.
6.
Connect electrical connector to the run solenoid.
Note:
If there is no power to terminal 1 of the glow con-
troller, verify continuity of the circuitry  from the ignition
switch to the controller  and perform step 4 again  (see
Electrical Schematics and Diagrams in this chapter).
Electrical Systems (Rev. C)
Page 5 − 40
Reelmaster 3100−D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 264 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website