Battery Service
The battery is the heart of the electrical system. With
regular and proper service, battery life can be extend.
Additionally, battery and electrical component failure
can be prevented.
2
CAUTION
When working with batteries, use extreme cau-
tion to avoid splashing or spilling electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes. Always wear safety goggles and a face
shield when working with batteries.
1
Figure 26
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80oF (26.7oC)
1.
Knobs
2.
Battery cover
Discharged: less than 1.240
Battery Specifications
BCI Group Size 55:
450
CCA at 0o F (−17.8o C)
1
Reserve Capacity of 60 minutes at 80oF (26.7oC)
2
Dimensions (including terminal posts and caps)
Length
Width
Height
8.90 inches (22.61 cm)
6.03 inches (15.31 cm)
8.49 inches (21.56 cm)
Removal (Fig. 26 and 27)
IMPORTANT: Be careful not to damage terminal
posts or cable connectors when removing the bat-
tery cables.
Figure 27
1.
tery retainer securing the back of the battery to the bat-
tery support.
Remove battery cover from the frame. Loosen bat-
1.
Ground cable
2.
Positive cable
IMPORTANT: Before cleaning the battery, tape or
block vent holes to the filler caps and make sure the
caps are on tightly.
2.
cable from battery. This should prevent short circuiting
the battery, other components, or the operators hands.
Loosen nut on ground cable (−) post first and remove
C. Check for signs of wetness or leakage on the top
of the battery which might indicate a loose or missing
filler cap, overcharging, loose terminal post, or over-
filling. Also, check battery case for dirt and oil. Clean
the battery with a solution of baking soda and water,
then rinse it with clean water.
3.
cable from battery.
Loosen nut on positive (+) cable post and remove
4.
5.
Make sure battery vent caps are on tightly.
Remove battery from the battery compartment to a
service area to allow better access for service.
D. Check that the cover seal is not broken away. Re-
place the battery if the seal is broken or leaking.
Inspection, Maintenance, and Testing
E. Check the electrolyte level in each cell. If the level
is below the tops of the plates in any cell, fill all cells
with distilled water between the minimum and maxi-
mum fill lines. Charge at 15 to 25 amps for 15 min-
utes to allow sufficient mixing of the electrolyte.
1.
Perform following inspections and maintenance:
A. Check for cracks. Replace battery if cracked or
leaking.
B. Check battery terminal posts for corrosion. Use
wire brush to clean corrosion from posts.
Reelmaster 3100−D
Page 5 − 43
Electrical Systems (Rev. C)
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Reelmaster 3100-D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)