Toro 02097SL Rev E Service Manual Groundsmaster 4000 D Service Manual

Fuel Gauge
The fuel gauge can be tested using a new  gauge as a
substitute or with the use of a DC voltage source and a
variable resistance box.
CAUTION
Make sure the voltage source is turned OFF be-
fore connecting it to the electrical circuit to avoid
electrical   shock  and   prevent   damaging   the
gauge.
VARIABLE
RESISTANCE
14
VDC + 0.01 VDC
1.
Connect fuel gauge  to the variable  resistance and
DC voltage source (Fig. 27).
+
NOTE:  When reading the  gauge test point, there  are
two white dots on the gauge face below the edge of the
glass cover for the each test point. For each variable re-
sistance setting, the  needle must be pointed  between
the two white dots.
Figure 27
1
2
2.
Take test point readings (Fig. 28).
IMPORTANT: Allow circuit to warm up for at least 5
minutes before taking test readings.
A.  Set variable resistance to 240 ohms. Apply a 14 +
0.01
VDC to the circuit. The needle should  point to
the left edge of the red area (empty).
B.  Set variable resistance to 33 ohms. The  needle
should point to the right edge of the green area (full).
3.
Turn  off  the  voltage  source.  Disconnect  voltage
source, gauge, and variable resistance.
3
Figure 28
1.
2.
Empty position
Full position
3.
Glass face edge
Groundsmaster 4000−D
Page 5 − 19
Electrical System
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 250 pages
Document TypeService Manual
LanguageEnglish
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website