Toro 02097SL Rev E Service Manual Groundsmaster 4000 D Service Manual

Procedure for Cutting Deck Circuit Pressure Test
Make sure hydraulic oil is at normal operating tem-
1.
perature by operating the machine for approximately 10
minutes. Make sure the hydraulic tank is full.
2.
lowered and off. Make sure engine is off and the parking
brake is engaged.
Parkmachineonalevelsurfacewiththecuttingunits
1
CAUTION
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS, and Pre-
cautions for Hydraulic Testing at the  beginning
of this section.
Figure 18
Front deck circuit pressure test port
1.
3.
manifold test port for the deck to be tested (Fig. 18, 19,
and 20).
Install test  gauge with  hydraulic hose attached  to
CAUTION
Keepawayfromdecksduringtesttopreventper-
sonal injury from the cutting blades.
1
4.
30
Start engine and move throttle to full speed (2730 +
RPM). Engage the cutting units.
Figure 19
Right deck circuit pressure test port
1.
5.
Watch pressure gauge carefully while mowing with
the machine.
6.
3000
tions.
Cutting deck circuit pressure should be from 1000 to
PSI and  will vary depending  on mowing  condi-
7.
Disengage cutting units. Shut off engine.
8.
Disconnect test gauge with hose from manifold test
port.
1
Figure 20
1.
Left deck circuit pressure test port
Groundsmaster 4000--D
Page 4 -- 29
Hydraulic System (Rev. B)
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 250 pages
Document TypeService Manual
LanguageEnglish
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website