Temperature Gauge
The  temperature gauge  can  be  tested using  a  new
gauge as  a substitute  or by the  use of  a DC  voltage
source and a variable resistance box.
CAUTION
Make sure the voltage source is turned OFF be-
fore connecting variable resistance  to the elec-
trical circuit to avoid electrical shock and to pre-
vent damaging the gauge.
VARIABLE
RESISTANCE
14
VDC + 0.01 VDC
1.
Connect temperature  gauge to  the variable  resis-
tance and DC voltage source (Fig. 27).
+
NOTE:  When reading the  gauge test point, there  are
two white dots on the gauge face below the edge of the
glass cover for the each test point. For each variable re-
sistance setting, the  needle must be pointed  between
the two white dots.
Figure 35
1
2.
Take test point readings (Fig. 28).
2
IMPORTANT: Allow circuit to warm up for at least 5
minutes before taking test readings.
A.  Set variable resistance to 71 ohms. Apply a 14 +
0.01
VDC to the circuit. The needle should  point to
the middle of the green area (80oC).
B.  Set variable resistance to 38 ohms. The  needle
should  point   between  the  green   and  red   area
(105
oC).
3.
Turn  off  the  voltage  source.  Disconnect  voltage
source, gauge, and variable resistance.
3
Figure 36
1.
2.
Middle position
High temp position
3.
Edge of glass cover
Electrical System
Page 5 − 24
Groundsmaster 4000−D
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 250 pages
Document TypeService Manual
LanguageEnglish
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website