Battery Service
The battery  is the heart of  the electrical system.  With
regular and proper service, battery life can be extended.
Additionally,  battery and  electrical  component failure
can be prevented.
2
CAUTION
When working with  batteries, use extreme cau-
tion  to avoid  splashing  or spilling  electrolyte.
Electrolyte can destroy clothing and burn skin or
eyes.  Always wear  safety  goggles and  a  face
shield when working with batteries.
3
1
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80oF (26.7oC)
Discharged: less than 1.240
Figure 43
1.
2.
Negative cable
Positive cable
3.
Battery retainer
Battery Specifications
BCI Group Size 24
650
CCA at 0o F (−17.8o C)
Reserve Capacity of 110 minutes at 80oF (26.7oC)
D. Check that the cover seal is not broken away. Re-
place the battery if the seal is broken or leaking.
Dimensions (including terminal posts and caps)
Length
Width
Height
10.2 inches (25.9 cm)
6.64 inches (16.9 cm)
8.99 inches (22.8 cm)
E.  Check the electrolyte level in each cell. If the level
is below the tops of the plates in any cell, fill all cells
with distilled water between the minimum and maxi-
mum fill lines. Charge at 15 to 25 amps for 15  min-
utes to allow sufficient mixing of the electrolyte.
Removal and Installation (Fig. 43)
See Operator’s Manual for battery removal and installa-
tion information.
2.
Conduct a hydrometer test of the battery electrolyte.
NOTE:  Before connecting the negative (ground) cable,
connect a digital multimeter (set to amps) between the
negative battery post and  the negative (ground) cable
connector. The reading should be less than 0.1 amp. If
the reading is 0.1 amp or more, the unit’s electrical sys-
tem should be tested and repaired.
IMPORTANT: Make sure the area around the cells is
clean before opening the battery caps.
A.  Measure the specific gravity  of each cell with  a
hydrometer.  Draw  electrolyte   in  and  out  of   the
hydrometer barrel prior to taking a reading to warm−
up the hydrometer. At the  same time take the tem-
perature of the cell.
Inspection, Maintenance, and Testing
1.
Perform following inspections and maintenance:
B.  Temperature correct each cell reading. For each
10
oF (5.5oC) above 80oF (26.7oC) add 0.004 to the
specific gravity reading. For each  10oF (5.5oC) be-
low 80oF (26.7oC)  subtract 0.004 from the specific
A.  Check for cracks. Replace  battery if cracked or
leaking.
gravity reading.
B.  Check battery terminal posts for  corrosion. Use
wire brush to clean corrosion from posts.
Example: Cell Temperature
Cell Gravity
100oF
1.245
IMPORTANT: Before  cleaning  the battery,  tape or
block vent holes to the filler caps and make sure the
caps are on tightly.
100
(37.7
20
(11
oF minus 80oF equals 20oF
oC minus 26.7oC equals 11.0oC)
oF    multiply by 0.004/10oF equals 0.008
oC    multiply by 0.004/5.5oC equals 0.008)
C. Check for signs of wetness or leakage on the top
of the battery which might indicate a loose or missing
filler cap, overcharging, loose terminal post, or over-
filling. Also, check battery case for dirt and oil. Clean
the battery with a solution of baking soda and water,
then rinse it with clean water.
ADD (conversion above)
Correction to 80oF (26.7oC)
0.008
1.253
Groundsmaster 4000−D
Page 5 − 29
Electrical System
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 250 pages
Document TypeService Manual
LanguageEnglish
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website