8.
thrust bearing (13), second thrust race (12), and second
retaining ring (3) onto drive shaft (21). Position washer
Place exterior  retaining  ring (3),  thrust race  (12),
20.Secure  control   assembly  with  six   socket  head
screws (17). Torque screws from 40 to 48 in--lb (4.5 to
5.4 N--m).
(24)
and shaft seal (25) onto shaft.
21.Install
control arm (27) onto control assembly input
9.
(25)
Install shaft assembly into front ofhousing. Seat seal
into position with seal driver and retain with interior
shaft. Retain with lock washer (23) and nut (22). Torque
nut from 4 to 6 ft--lb (5 to 8 N--m).
retaining ring (2).
22.Install
remaining  plugs  that  were  removed  from
10.Install
servo piston follower (8) onto camplate dowel
pump. Torque 3/4 in. plug from 21 to 24 ft--lb (28 to 32
N--m). Torque 1--1/4 in. plug from 40 to 45 ft--lb (54 to 61
N--m).
pin. Install  camplate (11)  carefully onto  bushing (44)
(coat bushing surface with hydraulic oil), aligning servo
piston follower (8) with slot in servo piston assembly (7).
11.
Position housing  in  a horizontal  position. Holding
camplate (11) in position with screw driver through con-
troller linkage passageway at the top of housing, place
rotatingkitassembly(6)overshaftandintohousinguntil
pistons are against camplate (11). Make sure all parts
are in housing completely and are properly positioned.
Returnthepumptothevisewithopenendofhousingup,
clamping housing on the outer portion of the flange.
12.Install
gasket (32) onto housing.
13.If
necessary, press new bearing (45) and roll pin (38)
inbackplate(20)todimensionshowninFigure43.Note:
Bearing should be installed with the numbered end out-
ward. Roll  pin should  be  installed with  split oriented
away from bearing.
14.Install
new o--ring on relief valves (16 & 26). Install
relief valve in the cavity in backplate that it was removed
and torque from 100 to 110 ft--lb (136 to 149 N--m).
15.Install
new o--ring on bypass valve  (14). Install by-
pass valve  (14) into backplate (20).  Note: Make sure
paddle of bypass valve is perpendicular to relief  valve
axis prior to installing or damage could result.
16.Apply
a small amount of petroleum jelly to the steel
side of valve plate (18) to hold in place for installation.
Aligning the index pin, place the valve plate (18) in posi-
tion onto  the  backplate (20),  with  steel side  against
backplate.
17.Install
backplateassembly(20)ontohousingassem-
bly (19). Make sure ports are positioned correctly, and
that valve plate (18) and gasket (32) stay in place.
18.Retain
backplate  (20) with  four cap  screws  (15).
Torque cap screws from 27 to 31 (37 to 42 N--m).
19.Install
control  housing gasket  (34)  onto housing.
Install orifices (30) into servo control assembly (28) and
retain in position with petroleum jelly. Position the feed-
back link  at 90  degrees from  control housing.  Install
manual servo control assembly (28) onto housing mak-
ingsurefeedback  linkenteredsmallgrooveinservopis-
ton assembly (7).
Groundsmaster 4000--D
Page 4 -- 63
Hydraulic System (Rev. B)
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 250 pages
Document TypeService Manual
LanguageEnglish
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website