Toro 98957SL Rev B Sand Pro 2020 3020 5020 Service Manual

E.  Connect a battery load tester to the battery ter-
minals  following  the   manufacturer’s  instruc-
tions. Connect  a digital  multimeter to the  battery
terminals.
6.   Apply a light coat of grease on all battery posts and
cable connectors to reduce corrosion after connections
are made.
7.
Connect a digital multimeter (set to amps) between
F.  Apply a test load of one half the Cranking Perfor-
mance(seeBatterySpecifications)ratingofthebat-
tery for 15 seconds.
the  negative battery  post  and the  negative  (ground)
cable connector. The  reading should be less  than 0.1
amp. If the reading is 0.1 amp or more, the unit’s electri-
cal system should be tested and repaired.
G. Take a voltage  reading at 15 seconds, then re-
move the load.
8.   Connect  negative (ground) cable connector to the
negative battery post. Tighten  cap screw and lock nut
with two wrenches.
H. Using  the table below, determine the minimum
voltage for the cell temperature reading.
Charging
Minimum
Voltage
Battery Electrolyte
Temperature
To minimize possible damage to  the battery and allow
the battery to be fully charged, the slow charging meth-
od is presented here. This charging method can be ac-
complished  with  a  constant  current  battery  charger
which is available in most shops.
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
70_F (and up)
60_F
21.1_C (and up)
15.6_C
10.0_C
4.4_C
50_F
40_F
30_F
–1.1_C
–6.7_C
–12.2_C
–17.8_C
CAUTION
20_F
10_F
Follow the manufacturer’s instructions when us-
ing a battery charger.
0_F
NOTE:  Using specific gravity of the battery cells is the
most accurate method of determining battery condition.
I.   If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
1.
Determine the battery charge level  from either its
open specific gravity or circuit voltage.
Installation (Fig. 10 and 11)
IMPORTANT: To  prevent  possible electrical  prob-
lems, install only a fully charged battery.
Battery Charge
Level
Specific
Gravity
Open Circuit
Voltage
100%
75%
50%
25%
0%
1.265
1.225
1.190
1.155
1.120
12.68
12.45
12.24
12.06
11.89
1.
off.
Make sure ignition  switch and all  accessories are
2.
painted if necessary.
Make sure  battery compartment  is clean  and re-
3.
Make sure all battery cables and connections are in
good  condition and  battery clamp  or  hold down  has
been repaired or replaced.
4.
Place battery in its compartment. Make sure battery
is level and flat. Connect positive cable connector onto
positive battery  post. Tighten cap  screw and  lock nut
with two wrenches.
5.
Secure battery clamp  or hold down  to the battery
and hold down rod with the washer and wing nut. Do not
overtighten to prevent cracking or distorting the battery
case.
Electrical Systems
Page 5 – 16
Sand Pro 2020/3020/5020
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 170 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website