Lift Circuit: Raise Cutting Decks
A four section gear pump is coupled to the piston (trac-
tion) pump. Gear pump section (P4) supplies hydraulic
flowtotheliftcontrolmanifoldandliftcylinders.Thegear
pump takes its suction from the hydraulic reservoir.
LIFT CIRCUIT: NOT RAISING OR LOWERING
The lift control  manifold includes three  (3) electrically
operated valves. Solenoid valve (S1) is used to direct oil
flowtoextendtheliftcylinders   whenenergized  orretract
them when de--energized. Solenoid  valve (S2) allows
hydraulic flow from the rod end of the lift cylinders when
energized and prevents oil passage from  the lift cylin-
ders  when   de--energized.  Proportional  relief   valve
(PRV) is used to control  the operation of the manifold
logic cartridge (LC)andalsoacts  asacircuit reliefvalve.
While operating the  machine during conditions  of not
raising or lowering the cutting decks (joystick in the neu-
tral (center)  position) (Fig. 17),  all of  the lift manifold
valves (S1, S2 and PRV)arede--energized.Thede--en-
ergized relief valve (PRV) allows hydraulic flow to return
to tank through the manifold. This flow causes a pres-
sure differential that shifts the logic cartridge (LC) which
allows pump flow to bypass  the lift cylinders. Flow re-
turns to the oil filter and then to the hydraulic reservoir.
S1, S2 AND PRV
DE--ENERGIZED
LC SHIFTED
Raise Cutting Decks (Fig. 16)
LIFT
CONTROL
MANIFOLD
Whenthejoystickismovedtotheraiseposition,thecon-
troller energizes theproportional relief valve (PRV).The
energized relief valve (PRV) prevents flow through the
valve which returns logic cartridge LC to the unshifted
position. With  lift manifold  cartridges in  this position,
pump flow is directed to the rod end of all lift cylinders to
retract the cylinders and raise all cutting decks. Flow to
the lift cylinders bypasses the control manifold fixed ori-
fices to prevent flow restriction during deck raising.
FROM
PUMP P4
TO OIL
FILTER
Figure 17
Whilethecutting  decks are beingraised, theproportion-
al relief valve (PRV) has a secondary function as a cir-
cuit relief to limit  lift circuit pressure to 2000  PSI (138
bar). Lift circuit pressure can be monitored at lift control
manifold port G4.
When the  joystick is  returned to  the neutral  (center)
position, the proportional relief valve (PRV) is de--ener-
gized. The de--energized relief valve (PRV) allows hy-
draulic flow to return to tank through the manifold. This
flow causes a pressure differential that shifts  the logic
cartridge (LC) which allows pump flow to bypass the lift
cylinders. All lift cylinders and cutting decks are held in
the raised position by de--energized valve S2.
Groundsmaster 4300--D
Page 4 -- 17
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 255 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website