Toro 10178SL Service Manual Groundsmaster 4300 D Preface Publication

3.
tion.
Read Precautions For Hydraulic Testing in this sec-
11.If flow is less than 12.1 GPM (45.8 LPM) or a pres-
sureof1500PSI(103bar)cannotbeobtained,consider
that a  pump  problem exists.  Check for  restriction  in
pump intake line. If intake is not restricted, remove gear
pump and repair  or replace pump  as necessary (see
Gear Pump and Gear Pump Service in the Service and
Repairs section of this chapter).
CAUTION
Before opening hydraulic system, operate all hy-
draulic controls to relieve system pressure and
avoid injury from pressurized hydraulic oil. See
Relieving Hydraulic System Pressure in the Gen-
eral Information section of this chapter.
12.After testing is completed, make sure that engine is
stopped, then relieve  hydraulic system pressure  (see
Relieving Hydraulic System Pressure in the General In-
formation section of this chapter). Remove tester from
machine and connect hydraulic hose to gear pump fit-
ting.
4.
Raise and support operator seat to allow access to
hydraulic pump.
13.Lower
and secure operator seat.
5.
Identify suspected faulty pump section to be tested
(Fig. 48). Thoroughly clean junction of gear pump fitting
and hydraulic outlet hose. Disconnect hose from pump
fitting:
1
Pump section (P1) for rear cutting decks
Pump section (P2) for front cutting decks
2
IMPORTANT: Make sure  that the oil flow  indicator
arrow on the flow gauge is showing that the oil will
flowfromthegearpump,through   thetesterandinto
the hose.
3
6.
Install tester with pressure gauges and flow meter in
series between disconnected hose and gear pump fit-
ting.Make sure the flow controlvalve ontester isful-
ly open.
Figure 48
1.
2.
Gear pump assembly
Pump P1 outlet hose
3.
Pump P2 outlet hose
7.
After installing  tester, start  engine and  run at idle
speed. Check for any hydraulic leakage from test con-
nections and correct before proceeding with test.
8.
Make  sure the  parking  brake  is  engaged. Move
throttle to full speed (3200 RPM). DO NOT engage the
cutting decks. Use  a tachometer to verify  that engine
speed is correct.
IMPORTANT: The gear pump is a positive displace-
ment type. If pump flow is completely restricted or
stopped, damage to the pump, tester or other com-
ponents could occur.
9.
tester flow control valve until 1500 PSI (103 bar) is ob-
While watching pressure  gauges, slowly close the
tained on gauge.
FLOW TESTER READING TO BE: A pump in good
condition should have a flow of approximately 13.6
GPM (51.2 LPM) at 1500 PSI (103 bar).
10.Open
the tester flow control valve and stop the en-
gine. Record test results.
Groundsmaster 4300--D
Page 4 -- 47
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 255 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website