4.
hydraulic pump.
Raise and support operator seat to allow access to
13.After testing is completed, make sure that engine is
stopped, then relieve  hydraulic system pressure  (see
Relieving Hydraulic System Pressure in the General In-
formation section of this  chapter). Remove tester and
connect removed hydraulic hose to gear pump (P4) out-
let and lift control manifold P port.
5.
Thoroughly clean  both ends of the  hydraulic hose
that connects gear  pump (P4) outlet  (Fig. 54) and lift
control manifold P4 port. Remove  hydraulic hose. Ac-
cess to hydraulic hose at lift control manifold can be ob-
tained from below the machine.
14.Lower and secure operator seat.
IMPORTANT: Make sure  that the oil flow  indicator
arrow on the flow meter is showing that the oil will
flow from pump (P4), through the tester and to the
lift control manifold.
1
6.
Install tester with pressure gauges and flow meter in
place of the removed hydraulic hose. Connect tester in-
let hose to  the pump fitting. Connect  the tester outlet
hose to the lift control  manifold fitting. Make sure the
flow control valve on tester is fully open.
2
7.
Make sure thatthetraction pedalis inneutral andthe
parking brake is engaged.
8.
draulic leakage from test  connections and correct be-
fore proceeding with test.
Start engine and run at idle speed. Check for any hy-
Figure 54
1.
Gear pump (P4)
2.
Hydraulic hose
9.
tachometer to verify that engine speed is correct.
Move  throttle  to  full  speed  (3200 RPM).  Use  a
IMPORTANT: The gear pump is a positive displace-
ment type. If pump flow is completely restricted or
stopped, damage to the pump, tester or other com-
ponents could occur.
10.While
carefully watching  pressure gauges,  slowly
closethetesterflowcontrolvalveuntil1000PSI(70bar)
is obtained on gauge.
FLOW TESTER READING TO BE: A pump in good
condition should  have a flow of  approximately 3.2
GPM (11.9 LPM) at 1000 PSI (70 bar).
11.
Open the tester flow control valve, stop engine and
record test results.
12.If
flow is less than 2.8 GPM (10.6 LPM) or a pressure
of 1000 PSI (70 bar) cannot be obtained, consider that
a pump problem exists. Check for restriction in pump in-
take line. If intake is not restricted, remove gear pump
and repair  or replace  pump as necessary  (see Gear
Pump in the Service and Repairs section of this chap-
ter).
NOTE:  Iftheflowfromgearpump(P4)islow,theopera-
tion of all lift cylinders will be affected.
Groundsmaster 4300--D
Page 4 -- 53
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 255 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website