FLOW TESTER READING TO BE: A pump in good
condition should have a flow of approximately 4.9
GPM (18.5 LPM) at 800 PSI (55 bar).
CAUTION
11.
record test results.
Open the tester flow control valve, stop engine and
Before opening hydraulic system, operate all hy-
draulic controls to relieve system pressure and
avoid injury from pressurized hydraulic oil. See
Relieving Hydraulic System Pressure in the Gen-
eral Information section of this chapter.
12.If
flow is less than 4.4 GPM (16.6 LPM) or a pressure
of 800 PSI (55 bar) cannot be obtained, consider that a
pump problem exists. Check for restriction in pump in-
take line. If intake is not restricted, remove gear pump
and repair or replace pump as necessary (see Gear
Pump in the Service and Repairs section of this chap-
ter).
4.
Raise and support operator seat to allow access to
hydraulic pump.
5.
Thoroughly clean the ends of the hydraulic tubes
connected to the oil filter and traction pump inlets (Fig.
Disconnect hydraulic tubes from oil filter inlet and
NOTE: Iftheflowfromgearpump(P3)islow,theopera-
tion of both the charge circuit and the steering circuit will
be affected.
40).
traction pump inlet. Remove two (2) flange head screws
that secure oil filter adapter to frame. Remove oil filter
assembly and hydraulic tube from machine.
13.After
testing is completed, make sure that engine is
stopped, then relieve hydraulic system pressure (see
Relieving Hydraulic System Pressure in the General In-
formation section of this chapter). Remove tester and
then install oil filter assembly and hydraulic tube to ma-
chine.
IMPORTANT: Make sure that the oil flow indicator
arrow on the flow meter is showing that the oil will
flow from the hydraulic tube, through the tester and
into the traction pump.
6.
Install tester with pressure gauges and flow meter in
14.Lower
and secure operator seat.
place of the removed oil filter assembly and hydraulic
tube. Connect tester inlet hose to the hydraulic tube.
Connect the tester outlet hose to the traction pump fit-
ting.Make sure the flow controlvalve ontester isful-
ly open.
4
7.
steering wheel is stationary and the parking brake is en-
gaged.
Make sure that the traction pedal is in neutral, the
2
3
1
8.
Start engine and run at idle speed. Check for any hy-
draulic leakage from test connections and correct be-
fore proceeding with test.
9.
tachometer to verify that engine speed is correct.
Move throttle to full speed (3200 RPM). Use a
IMPORTANT: The gear pump is a positive displace-
ment type. If pump flow is completely restricted or
stopped, damage to the pump, tester or other com-
ponents could occur.
Figure 40
1.
2.
Hydraulic tube
Oil filter / filter adapter
3.
4.
Hydraulic tube
Gear Pump (P3)
10.While
watching pressure gauges, slowly close the
tester flow control valve until 800 PSI (55 bar) is ob-
tained on gauge.
Groundsmaster 4300--D
Page 4 -- 39
Hydraulic System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 4300 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)