9.
control valve on tester until a pressure of 1200 PSI (83
bar) is obtained.
While watching pressure gauges, slowly close flow
CAUTION
10.After
achieving 1200 PSI (83 bar), place discon-
Before opening hydraulic system, operate all hy-
draulic controls to relieve system pressure and
avoid injury from pressurized hydraulic oil. See
Relieving Hydraulic System Pressure in the Gen-
eral Information section of this chapter.
nected motor case drain hose into a container gra-
duated inounces ormilliliters (e.g.Toro#TOR4077)and
collect hydraulic fluid for 15 seconds. After 15 sec-
onds, remove hose end from container. Then move the
PTO switch to OFF, open the tester flow control valve
and stop the engine.
NOTE: The deck motors are connected in series. To
isolate a faulty motor, all motors in the circuit may have
to be tested by starting with the upstream motor first.
11.
Identify amount of oil collected in the container. Re-
cord test results.
5.
For deck motor to be tested, thoroughly clean junc-
If flow was greater than 22.4 ounces (662 millili-
ters) (0.7 GPM/2.6 LPM), repair or replace the
tested deck motor (see Cutting Deck Motor Service
in the Service and Repairs section of this chapter).
tion of the motor case drain hose (small diameter hose)
where it connects to traction unit bulkhead (not at the
motor)(Fig.50).Disconnectthecasedrainhoseandput
a steel cap on the fitting at the traction unit. Leave the
case drain hose from the motor open and place open
end of disconnected hose into a drain pan.
If flow is less than 22.4 ounces (662 milliliters) (0.7
GPM/2.6 LPM), the tested motor does not have ex-
cessive leakage.
IMPORTANT: Make sure that the oil flow indicator
arrow on the flow gauge is showing that the oil will
flow from the deck motor, through the tester and
into the return hose.
12.After
testing is completed, make sure that engine is
stopped, then relieve hydraulic system pressure (see
Relieving Hydraulic System Pressure in the General In-
formation section of this chapter). Disconnect tester
from motor and return hose. Connect return hose to the
deck motor.Remove plug frommachine bulkhead fitting
and connect case drain hose to the fitting.
6.
On deck motor to be tested, thoroughly clean junc-
tion of hydraulic return hose and deck motor fitting (Fig.
Disconnectreturnhosefromthemotor.Installtester
50).
with pressure gauges and flow meter in series with the
motor and disconnected return hose. Make sure the
flow control valve on tester is fully open.
13.If
necessary, perform motor efficiency test on other
deck motors.
NOTE: Use a graduated container, special tool
TOR4077, to measure case drain leakage (Fig. 49).
2
7.
Start engine and run at idle speed. Check for any hy-
draulic leakage from test connections and correct be-
fore proceeding with test.
3
CAUTION
Cutting deck blades will rotate when performing
themotorefficiencytest.Keepawayfromcutting
decksduring testtopreventpersonal injuryfrom
rotating blades. Do not stand in front of the ma-
chine.
1
Figure 50
8.
RPM). Press PTO switch to ON. Move joystick lever for-
ward to engage cutting decks.
Sit on seat and move throttle to full speed (3200
1.
2.
Case drain hose
Bulkhead fitting
3.
Return hose
Groundsmaster 4300--D
Page 4 -- 49
Hydraulic System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 4300 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |