High Temperature Shutdown Switch
The high temperature shutdown switch is located on the
water  pump housing.  There  is  a blue/white  wire  at-
tached to the shutdown switch.
6.  After testing is complete, install switch to the engine
housing.
A.  Clean threads of housing and switch thoroughly.
Apply thread sealant to the threads of the switch.
The Standard Control Module monitors the operation of
the high  temperature shutdown  switch. If  the ignition
switch is in  the ON position and the  high temperature
shutdown switch has  closed due to excessive coolant
temperature, the Module Over Temperature Shutdown
input LED should be illuminated and the engine should
shut down.
B.  Thread switch  into the  housing. Torque  switch
from 16 to 20 ft−lb (21.7 to 27.1 N−m).
C. Reconnect wire to switch.
7.
Fill engine cooling system (see Traction Unit Opera-
tor’s Manual).
Testing
CAUTION
Make sure  engine is  cool before  removing the
temperature switch from engine.
1.
Lower the coolant level in the engine and remove the
1
high temperature shutdown switch from the engine.
2.
thermometer and slowly heat the oil (Fig. 16).
Put the end of the switch in a container of oil with a
Figure 14
High temperature switch (gasoline engine)
1.
CAUTION
Handle the hot oil  with extreme care to prevent
personal injury or fire.
3.
Check  resistance of  the switch  with  a multimeter
(ohms setting)  as the  oil temperature  increases. The
high temperature shutdown switch is normally open.
1
A.  On the Groundsmaster 3280−D (diesel engine),
the high temperature shutdown switch should close
between 225o and 235oF (107o and 113oC).
Figure 15
High temperature switch (diesel engine)
1.
B.  On the Groundsmaster 3320 (gasoline  engine),
the high temperature shutdown switch should close
at approximately 238oF (114oC).
4.
Allow oil to cool while observing temperature.
A.  On the Groundsmaster 3280−D (diesel engine),
the high temperature shutdown switch should open
at approximately 219oF (104oC).
B.  On the Groundsmaster 3320 (gasoline  engine),
the high temperature shutdown switch should open
at approximately 232oF (111oC).
Figure 16
5.
Replace switch if specifications are not met.
Electrical System
Page 6 − 14
Groundsmaster 3280−D/3320
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 260 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website