Toro 05138SL Rev A Service Manual Groundsmaster 3280 D 3320 Preface Publication

Fuel Stop Solenoid (Groundsmaster 3280−D)
The  fuel  stop solenoid  used  on  the  Groundsmaster
3280−D
engine to run. The solenoid is mounted to the injection
pump on the engine (Fig. 30).
(diesel engine) must be energized for the diesel
2
In Place Testing
NOTE:  Prior to taking small resistance readings with a
digital multimeter, short the test leads together. The me-
ter  will display  a  small resistance  value (usually  0.5
ohms or less). This resistance is due to the internal re-
sistance of the meter and test leads. Subtract this value
from the measured value of the component you are test-
ing.
1
Figure 30
1.
Injection pump
2.
Fuel stop solenoid
1.
2.
pull coil terminal and the other test lead to the fuel stop
solenoid frame (ground) (Fig. 31). The resistance of the
pull coil should be less than 1 ohm (but not zero).
Disconnect wire harness connector from solenoid.
Using a digital multimeter, touch one test lead to the
2
1
3.
Using a digital multimeter, touch one test lead to the
hold coil terminal and the other test lead to the fuel stop
solenoid frame (ground) (Fig. 31). The resistance of the
hold coil should be approximately 15 ohms.
3
4.
Connect solenoid to the wiring harness.
Figure 31
1.
2.
Fuel stop solenoid
Pull coil terminal
3.
Hold coil terminal
Live testing
1.
Disconnect wire harness connector from solenoid.
NOTE:  The solenoid may be removed from the engine
or tested in place.
2.
If the  solenoid is  removed from the  engine, make
sure that the solenoid plunger moves freely and is free
of dirt, debris and corrosion.
NOTE:  When testing run solenoid, use test leads with
at least 14 gauge wire.
3.
Connect  a positive  (+)  test  lead from  a  12  VDC
source to the pull coil and hold coil terminals.
4.
Touch  a negative  (−)  test lead  from  the 12  VDC
source to the fuel stop solenoid frame (ground) (Fig. 31).
The solenoid should engage, making an audible “click,”
and the plunger should retract.
5.
Remove positive (+) voltage from the pull coil termi-
nal. The solenoid should stay engaged.
6.
Remove positive (+) voltage from the hold coil termi-
nal. The solenoid should release.
7.
Reconnect the wires to the solenoid.
Electrical System
Page 6 − 22
Groundsmaster 3280−D/3320
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 260 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website