Transport, Alarm Silence, and Temperature Override Switches
The transport, alarm silence, and temperature override
rocker switches are located on the control console (Fig.
18).
These switches have common switching logic.
3
The switch terminals are marked as shown in Figure 19
and Figure 20. The circuitry of these switches is shown
in the chart below. With the use of a multimeter (ohms
setting), the switch functions may be tested to determine
whether continuity exists between the various terminals
for each position. Verify continuity between switch termi-
nals.
2
1
SWITCH
POSITION
NORMAL
CIRCUITS
OTHER
CIRCUITS
ON
2 + 3
1 + 2
5 + 6
4 + 5
Figure 18
OFF
1.
2.
Transport switch
3.
Temp. override switch
Alarm silence switch
NOTE: Terminals 7 (−) and 8 (+) on alarm silence and
temperature override switches are for the switch light.
4
1
5
2
6
3
BACK OF TRANSPORT SWITCH
Figure 19
7
8
4
1
5
2
6
3
BACK OF ALARM SILENCE AND
TEMPERATURE OVERRIDE SWITCHES
Figure 20
Electrical System
Page 5 − 14
Groundsmaster 4100−D
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 4100 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |