Toro 03116SL Rev E Service Manual Groundsmaster 4100 D Preface Publication

Battery Storage
If the machine will be stored for more than 30 days:
4.  Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
1.
Remove the battery and charge it fully (see Battery
Service).
5.  To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service).
2.
3.
Either store battery on a shelf or on the machine.
Leave cables disconnected if the battery is stored on
the machine.
Battery Care
1.
Battery  electrolyte  level  must  be  properly  main-
3.  Battery cables must be tight on terminals to provide
good electrical contact.
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more  rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Connecting cables to the wrong post could re-
sult in  personal injury  and/or damage to  the
electrical system.
WARNING
Wear safety goggles and rubber gloves when
working with  electrolyte. Charge battery  in a
well  ventilated   place  so   gasses  produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from  the battery; do not smoke.
Nausea may result if the gases are inhaled. Un-
plug charger from electrical outlet before con-
necting or disconnecting  charger leads to or
from battery posts.
4.
If corrosion occurs at terminals, disconnect  cables.
Always  disconnect   negative  (−)   cable  first.   Clean
clamps  and  terminals  separately.  Reconnect cables
with positive (+) cable first. Coat battery posts and cable
connectors  with   skin−over   grease  (Toro   Part  No.
505-165)
or petroleum jelly to prevent corrosion.
5.
and every 30 days if machine is in storage.
Check electrolyte  level  every 25  operating hours,
6.
Maintain cell level with distilled or demineralized wa-
ter. Do not fill cells above the fill line.
IMPORTANT: Do  not remove fill  caps while clean-
ing.
2.
Check  battery condition  weekly or  after  every 50
hours of  operation. Keep terminals  and entire battery
case clean because a dirty battery will discharge slowly.
A.  Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B.  Coat battery  posts  and  cable connectors  with
skin−over grease (Toro Part No. 505-165) or petro-
leum jelly to prevent corrosion.
Electrical System
Page 5 − 32    Rev. E
Groundsmaster 4100−D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 258 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website