PTO Solenoid Valve Coil
The hydraulic system on the Groundsmaster 7200 and
7210
uses a solenoid valve coil on the front of the trans-
mission (Fig. 22). When the solenoid valve coil is ener-
gized, hydraulic flow is directed to operate the PTO
system.
The Standard Control Module (SCM) provides current to
the solenoid valve coil based on the position of several
inputs. The PTO LED on the SCM will be illuminated
when the solenoid valve coil is energized.
Testing
2
NOTE: The solenoid does not have to be removed from
the cartridge valve for testing.
1.
plug wire harness electrical connector from solenoid
valve coil.
Make sure ignition switch is in the OFF position. Un-
1
3
NOTE: Prior to taking small resistance readings with a
digital multimeter, short the test leads together. The me-
ter will display a small resistance value (usually 0.5
ohms or less). This resistance is due to the internal re-
sistance of the meter and test leads. Subtract this value
from from the measured value of the component you are
testing.
Figure 22
1.
2.
Transmission
3.
Coil connector
Solenoid valve and coil
2.
connector terminals. Resistance of the solenoid coil
Measure resistance between the two solenoid coil
should be approximately 7.5 ohms.
3.
4.
noid Valve Coil in the Service and Repairs section of this
chapter.
Connect wire harness connector to the solenoid coil.
If solenoid coil needs replacement, see PTO Sole-
Groundsmaster 7200/7210
Page 5 – 19
Electrical System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 7200, Toro Groundsmaster 7210 |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)
My mower is a TORO 7210.
Start fuse defection. Why ?