Toro 07150SL Groundsmaster 7200 7210 Service Manual

High Temperature Shutdown Switch
The high temperature shutdown switch is located on the
water pump  housing (Fig.  29). The  high temperature
5.  Replace  shutdown switch  if specifications  are not
met.
shutdown switch is normally open and closes when en-
gine coolant temperature reaches approximately 240oF
6.
the engine housing.
After testing is complete, install shutdown switch to
(115
oC). When excessive  engine coolant temperature
causes the shutdown switch to close, the engine shuts
down. There is a blue/white  wire attached to the shut-
down switch.
A.  Clean threads of housing and switch thoroughly.
Apply thread sealant to the threads of the switch.
B.  Thread switch  into the  housing. Torque  switch
from 22 to 28 ft–lb (29.4 to 39.2 N–m).
The Standard Control Module (SCM) monitors  the op-
eration of the high temperature shutdown switch. If ex-
cessive engine  coolant  temperature causes  the high
temperature shutdown switch  to close, the High  Tem-
perature Shutdown LED on the SCM will be illuminated.
The switch and its circuit wiring should be tested using
the SCM before performing the following testing proce-
dure.
C. Reconnect harness wire to shutdown switch.
7.
8.
Fill engine cooling system.
Lower and secure hood.
Testing
1.
Park machine on a level surface, lower cutting deck
(or implement), stop engine, apply parking brake and re-
move key from  ignition switch. Open hood to  gain ac-
cess to engine.
1
CAUTION
Make sure  engine is  cool before  removing the
high temperature shutdown switch from engine.
Do not open radiator cap or  drain coolant if the
radiator or engine is hot. Pressurized, hot  cool-
ant can escape and cause burns.
Figure 29
High temperature shutdown switch
1.
2.
Lower the coolant level in the engine and remove the
high temperature shutdown switch from the engine.
3.
thermometer and slowly heat the oil (Fig. 30).
Put the end of the switch in a container of oil with a
CAUTION
Handle the hot oil  with extreme care to prevent
personal injury or fire.
Figure 30
4.
(ohms setting)  as the  oil temperature  increases. The
Check  resistance of  the switch  with  a multimeter
high temperature shutdown switch is normally open and
should close from 234o to 244oF (112o to 118oC).
Groundsmaster 7200/7210
Page 5 – 23
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 226 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

One thought on “Toro 07150SL Groundsmaster 7200 7210 Service Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website