Test Operation
CLEAN ROD
OR
1.
Place ignition switch  in the ON position.  DO NOT
SCREWDRIVER
VALVE ASSEMBLY
PLUG REMOVED
START ENGINE. Move leak detector switch downward
and hold. After the one second time delay elapses, the
alarm should sound.
WARNING
BUZZER
SOUNDS
SOLENOID
RETURN
VALVE
2.
Release leak detector switch.
CLOSED
3.
Remove cover  plate from  leak detector.  Remove
plug from valve assembly.
4.
Insert clean rod or screw driver into valve assembly
and gently push  down on switch float (Fig.  15). Alarm
should sound after one second delay.
PRESS DOWN ON
SWITCH FLOAT
TESTING SWITCH FLOAT
5.
Release float; alarm should stop sounding.
6.
If alarm fails to stop sounding, turn ignition switch to
Figure 15
OFF position. Locate solenoid  on leak detector. Swap
solenoid wires and repeat steps 4 and 5.
7.
Install plug  to valve  assembly and  cover plate to
tank. Move ignition switch to OFF position.
Electrical System (Rev. C)
Greensmaster 3250−D
Page 5 − 14
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 308 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website