Lower Reels Time Delay
This is a solid state timer. Upon the application of power,
the load is energized and the time delay is started. After
6
seconds the load is de−energized.
1.
Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After 6 seconds, there should
be no voltage across the load.
TIME
DELAY
2.
Disconnect timer from 12VDC source and test load.
Figure 23
+
−
INPUT VOLTAGE
LOAD
3
2
1
TIMING
RESISTOR
4
5
Figure 24
Greensmaster 3250−D
Page 5 − 19 Rev. H