General Information
Operator’s Manual
The Operator’s Manual provides information regarding
the operation, general maintenance  and maintenance
intervals for your Groundsmaster machine. Refer to the
Operator’s Manual for additional information when ser-
vicing the machine.
Toro Electronic Controllers (TEC)
Groundsmaster 5900 and 5910 machines  use two (2)
Toro Electronic Controllers (TEC) to manage machine
electrical functions. The controllers are microprocessor
controlled that sense the condition of various switches
(inputs) and direct electrical power to control appropri-
ate machine  functions (outputs) based  on the inputs.
Communication between the  two Toro controllers, the
Cummins engine controller and the Info Center Display
is provided with a CAN bus system. The status of inputs
to the controllers as well as outputs from the controllers
can be monitored with the Info Center Display.
IMPORTANT: Before performing any welding on the
machine, disconnect  the  battery cables  from the
batteries, disconnect the wire harness connectors
from both Toro Electronic  Controllers, disconnect
the wire harness connectors from the engine con-
troller and disconnect the terminal connector from
the alternator  to prevent  damage to  the machine
electrical system.
The controllers appear identical but they are different in
termsoftheconnectorsandinternalhardware.Theyare
arranged in ”master / slave” configuration and therefore
cannotbeinterchanged.TheTEC--5002mastercontrol-
ler is responsible for powering up  both the TEC--5001
slavecontroller andtheCummins  engine controller.The
TEC--5002 also controls the engine start circuit.
Cummins Engine Electronic Control Module (ECM)
The Cummins engine thatis usedin theGroundsmaster
5900
and  5910  uses  an  electronic  control  module
(ECM) for engine management  and also to communi-
cate with the TEC controllers and the Info Center  Dis-
play   on  the   machine.  All   engine  ECM   electrical
connectors should be plugged into the controller before
the machine ignition switch ismoved fromtheOFFposi-
tion to either the RUN or START position. If the engine
ECM is to be disconnected for any reason, make sure
thatthe ignitionswitch isin  theOFF positionwith thekey
removed before disconnecting the engine ECM.
Electrical System
Page 5 -- 2
Groundsmaster 5900/5910
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 374 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website