Toro 10176SL Service Manual Models 30448 30446 Groundsmaster 4000 4010 D D Preface

Procedure  for  Engine  Cooling  Fan  Circuit  Gear
Pump Flow Test
6.  While watching tester pressure gauges, slowly close
tester flow control valve until 1000  PSI (69 bar) is ob-
tained on gauge. Verify engine  speed continues to be
1.
Make sure hydraulic oil is at normal operating tem-
2870
RPM.
perature  by  operating  the  machine  under  load  for
approximately ten (10) minutes. Make sure the hydrau-
lic tank is full.
GAUGE READING  TO BE:  Flow approximately 7
GPM (26 LPM) at 1000 PSI (69 bar).
2.
Park machine  on  a level  surface with  the cutting
NOTE:  If engine speed drops below 2870 RPM, pump
flow will decrease.
decks lowered and off. Make sure engine is off and the
parking brake is applied. Raise and support seat to gain
access to the gear pump.
7.
Open tester flow control valve, stop engine and re-
cord test results.
8.
If a pressure of 1000 PSI (69 bar) could not be ob-
CAUTION
tained or flow is lower than 6 GPM (23 LPM), check for
restriction in pump  intake line. If  intake line is not  re-
stricted, consider  that  gear pump  section for  engine
cooling fan circuit is worn or damaged.
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS and Pre-
cautions for Hydraulic Testing at the  beginning
of this section.
9.  When testing is complete, remove tester and recon-
nect hose to pump fitting.
3.
With the engine off and cutting decks lowered, dis-
connect the hydraulic hose from the 90o fitting in the last
gear pump section  which supplies the engine  cooling
fan circuit (Fig. 54).
2
IMPORTANT: Make sure  that the oil flow  indicator
arrow on the flow gauge is showing that the oil will
flow from the pump section, through the tester and
into the hydraulic hose.
1
4
4.
the fitting and  the disconnected hose.  Make sure the
flow control valve on tester is fully open.
Install tester (flow and pressure) in series between
IMPORTANT: The pump is a positive displacement
type.  If   pump  flow  is  completely   restricted  or
stopped, damage to the pump, tester or other com-
ponents could occur.
3
Figure 54
5.
(2870
Start the engine and move throttle to high idle speed
RPM). DO NOT engage the cutting decks.
1.
2.
Gear pump
Fan drive manifold
3.
4.
Engine cooling hose
90   fitting
o
Groundsmaster 4000--D/4010--D
Page 4 -- 69
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website