Start and Air Conditioning (Groundsmaster 4010--D) Relays
When energized by the TEC--5002 controller, the start
relay is used to provide current to the engine starter mo-
tor solenoid. The start relay is located at the power cen-
ter behind the operator seat (Fig. 41).
nals 30 and 87A as +12  VDC is applied and removed
from terminal 85.
9.
leads from the relay terminals. Secure relay tomounting
bracket and connect wire harness connector to relay.
After testing, disconnect voltage and multimeter test
An identical relay is used to control the air conditioning
electrical power circuit on the Groundsmaster 4010--D.
When energized by theair conditioning switch, therelay
provides current  for the air  conditioning components.
The relay  is attached to the  cab headliner above  the
switch panel.
10.Secure
all removed components.  If battery cables
were disconnected,  connect positive (+) cable  first to
battery and then connect negative (--) cable to  battery
(see Battery Service in the Service and Repairs section
of this chapter).
The start and air conditioning relays are attached to the
wire harness with a five (5) wire connector (Fig. 42).
11.
Make sure that hood is secured.
Testing
1
1.
decks, stop engine, engage parking brake and remove
key from the ignition switch.
Park  machine  on  a  level  surface,  lower  cutting
3
10
9
2
2.
To access start relay:
5
A.  Raise and support hood.
B.  To make sure that machine  operation does not
occur unexpectedly, disconnect  negative (--) cable
from battery and then disconnect positive (+) cable
from battery (see Battery Service in the Service and
Repairs section of this chapter).
6
RIGHT
7
8
FRONT
4
C. Remove cover  (item 1) and heat shield (item 9)
from power center and  locate relay to be tested. If
necessary, remove two (2) flange nuts and carriage
screws that secure power center to tank support.
Figure 41
1.
2.
3.
4.
5.
Cover
6.
7.
8.
Mount
Screw
Lock nut
Flange nut (2 used)
Carriage screw (2 used)
Screw
Start relay
Heat shield
3.
To access air conditioning relay, remove screws that
secure switch panel to headliner in cab.
9.
10. Screw (2 used)
4.
move relay from mounting bracket for testing.
Disconnect wire harness connector from relay. Re-
3
1
4
5.
tween terminals 85 and 86 is from 71 to 88 ohms.
Using a  multimeter, verify  that coil  resistance be-
86
85
87A
87
6.
Connectmultimeter (ohmssetting) leadstorelayter-
minals 30 and  87. Ground terminal 86 and  apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
30
1
2
7.
Disconnect voltage from terminal 85 and multimeter
lead from terminal 87.
Figure 42
1.
2.
Coil terminal
Common terminal
3.
4.
Normally closed term.
Normally open term.
8.
minals 30 and 87A. Apply +12 VDC to terminal 85. The
relay should make and break continuity between termi-
Connectmultimeter (ohmssetting) leadstorelayter-
Electrical System
Page 5 -- 34
Groundsmaster 4000--D/4010--D
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website