Verify Diagnostic Display Output Functions
B. If the output LED’s are on as specified, but the
machine does not function properly, suspect a failed
electrical component, an open in the tested circuit or
a non-electrical problem (e.g. hydraulic component
problem). Repair as necessary.
The Diagnostic Display also has the ability to detect
which output solenoids or relays are energized by the
TECcontrollers.Thisisaquickwaytodetermineifama-
chine malfunction is electrical or hydraulic.
C. If each input switch is in the correct position and
functioning correctly, but the output LED’s are not
correctly illuminated, this indicates a TEC controller
problem. If this occurs, contact your Toro Distributor
for assistance.
NOTE: Anopenoutput(e.g.anunpluggedconnectoror
a broken wire) cannot be detected with the Diagnostic
Display.
1.
Park machine on a level surface, lower the cutting
decks, stop the engine and engage the parking brake.
7.
After output functions testing is complete, discon-
nect the Diagnostic Display connector from the harness
connector and plug loopback connector into wire har-
ness. Secure controller cover to frame.
2.
harness loopback connector (Fig. 11). Locate wire har-
ness communication port and loopback connector (Fig.
Remove the controller cover to allow access to wire
12).
connector.
Carefully unplug loopback connector from harness
2
1
3
3.
ConnecttheDiagnosticDisplayconnectortothehar-
nessconnector.Makesurecorrectoverlaydecalisposi-
tioned on the Diagnostic Display (Figs. 9 and 10).
4
4.
Turn the ignition switch to the ON position.
5
NOTE: The red text on the Diagnostic Display overlay
decal refers to input switches and the green text refers
to TEC outputs.
5.
Make sure that the “OUTPUTS DISPLAYED” LED,
on lower right column ofthe Diagnostic Display,isillumi-
nated. If “INPUTS DISPLAYED” LED is illuminated,
press the toggle button on the Diagnostic Display to
change the LED to “OUTPUTS DISPLAYED”.
RIGHT
FRONT
6
Figure 11
NOTE: It may be necessary to toggle between “IN-
PUTS DISPLAYED” and “OUTPUTS DISPLAYED” sev-
eral times to perform the following step. To change from
inputs to outputs, press toggle button once. This may be
done as often as required. Do not press and hold
toggle button.
1.
2.
3.
Controller cover
Screw (2 used)
4.
5.
6.
U--nut (2 used)
TEC--5001
TEC--5002
Flat washer (2 used)
1
2
6.
Sit on seat and attempt to operate the desired func-
tion of the machine. The appropriate output LED’s
should illuminate on the Diagnostic Display to indicate
that the TEC controller is turning on that function. The
GLOWPLUGS,HIRANGEandOKRUNoutputscanbe
checked with the ignition switch in the ON position and
the engine not running. For testing of the hydraulic sole-
noid outputs (e.g. ENABLE, C DECK RAISE, R DECK
FLOAT), the engine must be running.
A. IfthecorrectoutputLED’sdonotilluminate,verify
that the required input switches are in the necessary
positions to allow that function to occur.
3
Figure 12
1.
2.
Wire harness connector
Loopback connector
3.
Diagnostic display
Electrical System
Page 5 -- 10
Groundsmaster 4000--D/4010--D
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 10176SL, Toro Groundsmaster 30446, Toro Groundsmaster 30448, Toro Groundsmaster 4010 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)