Fuses
The fuse blocks are located in the power center under
the hood on the right side of the machine (Fig. 17).
Fuse Testing
Turn ignition switch to the ON position (do not start en-
gine). With the fuse installed in the fuse block, use a
multimeter to verify that 12 VDC exists at both of the ter-
minal test points on the fuse. If 12 VDC exists at one of
the fuse test points but not at the other, the fuse is faulty.
In addition to the fuses in the fuse blocks, a 40 amp fuse
(F5--1) is included in the wire harness to protect the pull
coil circuit for the engine run solenoid. This fuse resides
in a fuse holder near the starter motor (Fig. 17).
Fuse Identification and Function
If necessary, make sure that ignition switch is OFF and
key is removed from switch. Remove fuse from fuse
block and check that fuse has continuity across the fuse
terminals.
UseFigure18toidentifyeachindividualfuseanditscor-
rect amperage in the fuse block. The fuses have the fol-
lowing functions.
Fuse F1--1 (20 amp) protects engine starter circuit.
2
Fuse F1--3 (10 amp) protects light circuit on Ground-
smaster 4010--D.
Fuse F1--4 (10 amp) protects signal light circuit on
Groundsmaster 4010--D.
Fuse F2--2 (10 amp) protects operator seat circuit.
Fuse F2--3 (10 amp) protects power point circuit.
FuseF2--4(10amp)protectsmainpowersupplycircuit.
1
Fuse F3--1 (2 amp) protects logic power circuit to the
TEC--5002 controller.
Figure 17
Fuse F3--2 (7.5 amp) protects power supply for the
1.
Power center
2.
Fuse F5--1
TEC--5002 controller outputs.
Fuse F3--3 (7.5 amp) protects power supply for the
TEC--5002 controller outputs.
M1 (60A)
M2 (60A)
Fuse F3--4 (7.5 amp) protects power supply for the
TEC--5002 controller outputs.
F1
FRONT
Fuse F4--1 (2 amp) protects logic power circuit to the
TEC--5001 controller.
F2
F3
Fuse F4--2 (7.5 amp) protects power supply for the
TEC--5001 controller outputs.
Fuse F4--3 (7.5 amp) protects power supply for the
TEC--5001 controller outputs.
Fuse F4--4 (7.5 amp) protects power supply for the
TEC--5001 controller outputs.
F4
Fuse M1 (60A) protects engine glow plug circuit.
1
2
3
4
Fuse M2 (60A) protects operator cab circuit on Ground-
smaster 4010--D.
Figure 18
Groundsmaster 4000--D/4010--D
Page 5 -- 21
Electrical System
Product Specification
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 10176SL, Toro Groundsmaster 30446, Toro Groundsmaster 30448, Toro Groundsmaster 4010 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |