Toro 10176SL Service Manual Models 30448 30446 Groundsmaster 4000 4010 D D Preface

Toro Electronic Controllers (TEC)
Groundsmaster 4000--Dand4010--Dmachinesusetwo
Toro Electronic  Controllers (TEC) to  control electrical
system operation. The  controllers are attached to  the
operator platform under  the controller cover (Figs.  43
and 44).
IMPORTANT: Before performing welding on the ma-
chine, disconnect both  positive and negative bat-
tery  cables   from   the  battery,   disconnect  wire
harness connector from both of the TEC controllers
and disconnect the terminal connector from the al-
ternator.Thesestepswillpreventdamagetothema-
chine electrical system.
Logic power is provided to the controllers as long as the
battery cables are connected to the battery. A pair of 2
ampfuses(F3--1andF4--1)providecircuitprotectionfor
this logic power to the controllers.
1
RIGHT
The TEC--5002 master controller monitors the states of
the  following components  as  inputs:  ignition switch,
parking  brake  switch,   traction  neutral  switch,  seat
switch, engine oil pressure switch, flow divider switch,
Hi/Lowspeedswitch,hydraulic  temperature sender,en-
gine coolant  temperature sender,  engine cooling  fan
switch   and   optional    cruise   control   switches   (if
equipped).
FRONT
2
3
7
4
5
The TEC--5002 controller  controls electrical output  to
the TEC--5001 controller, hydraulic  fan drive manifold
solenoid coils (speed and direction), fuel pump, engine
run solenoid (hold coil), glow plug relay, start relay, high
temperature warning light, diagnostic light, audio alarm,
hydraulic 4WD manifold solenoid coil (flow divider), hy-
draulic traction  manifold solenoid coil (Hi/Low  speed)
and optional  cruise  control coil  (if equipped).  Circuit
protectionforTEC--5002outputsisprovidedbythree(3)
6
8
9
7.5
amp fuses (F3--2, F3--3 and F3--4).
The TEC--5001 slave controller monitors  the states of
the following components as inputs: ignition switch, cut-
ting deck  lift switches, PTO  switch and deck  position
switches.
Figure 43
1.
2.
3.
4.
5.
Controller cover
Screw (2 used)
Flat washer (2 used)
Flange nut (8 used)
Front cover mount
6.
7.
8.
9.
Cap screw (8 used)
U--nut (2 used)
TEC--5001 controller
TEC--5002 controller
The TEC--5001 controller  controls electrical output  to
thehydraulicPTOandliftmanifoldsolenoidcoils.Circuit
protectionforTEC--5001outputsisprovidedbythree(3)
7.5
amp fuses (F4--2, F4--3 and F4--4).
3
Because of the  solid state circuitry  built into the TEC
controllers, there is no method to test a controller direct-
ly. A controller may be damaged if an attempt is made
to test it with an electrical test device (e.g. digital multi-
meter or test light).
NOTE:  The TEC controllers used on the Groundsmas-
ter 4000 and 4010 are matched for correct machine op-
eration. If either of these components are replaced for
any  reason,   system  software  needs   to  be  repro-
grammed by your Toro Distributor.
1
2
Figure 44
1.
2.
TEC--5001 controller
TEC--5002 controller
3.
Operator seat
Groundsmaster 4000--D/4010--D
Page 5 -- 35
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 340 pages
Document TypeCatalog
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website