Service and Repairs
NOTE: For engine component repair information (e.g.
starter motor), see the Kubota Workshop Manual, Die-
sel Engine, 03--M--E3B Series at the end of Chapter 3
--
Kubota Diesel Engine.
Battery Storage
If the machine will be stored for more than 30 days:
4. Store battery ina cool atmosphere toavoid quick de-
terioration of the battery charge.
1.
Remove the battery and charge it fully (see Battery
Service in this section).
5. To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service in this section).
2.
3.
Either store battery on a shelf or on the machine.
Leave battery cables disconnected if the battery is
stored on the machine.
Battery Care
1.
Battery electrolyte level must be properly main-
3. Battery cables must be tight on terminals to provide
good electrical contact.
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Connecting battery cables to the wrong battery
post could result in personal injury and/or dam-
age to the electrical system.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced while
charging can dissipate. Since the gases are ex-
plosive, keep open flames and electrical sparks
away from the battery; do not smoke. Nausea
mayresultifthegasesareinhaled.Unplugchar-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
4.
If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Reconnect cables
with positive (+) cable first. Coat battery posts and cable
connectorswithbatteryterminalprotector(ToroPartNo.
107--0392)
or petroleum jelly to prevent corrosion.
5. Checkelectrolyte levelevery25operating hoursand
every 30 days if machine is in storage.
6.
Maintain cell level with distilled water. Do not fill cells
above the fill line.
IMPORTANT: Do not remove fill caps while clean-
ing.
2.
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
Check battery condition weekly or after every 50
A. Clean battery by washing entire case with a solu-
tionofbakingsodaandwater.Rinsewithclearwater.
B. Coatbatterypostsandcableconnectorswithbat-
tery terminal protector (Toro Part No. 107--0392) or
petroleum jelly to prevent corrosion.
Groundsmaster 4000--D/4010--D
Page 5 -- 47
Electrical System
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro Groundsmaster 10176SL, Toro Groundsmaster 30446, Toro Groundsmaster 30448, Toro Groundsmaster 4010 D |
Download File |
|
Document Type | Catalog |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)